schmersal_s_icon.png

HINGED SAFETY SWITCHES TVS410ST4-11/11I

Item number: 101184433

Downloads

TraceParts CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
Product type description:

TVS 410 (1)-(2)(3)(4)


(1)
SKScrew connection
CCCage clamp
ST1M12 connector bottom
ST2M12 connector top

(2)
11/112 NC contacts / 2 NO contacts (Caution! According to EN 60204-1, the versions with connector must only be used in PELV circuits. Only for ST1, ST2)

(3)
Uadjustable switching angle
IMounting inside (with fixed switching angle 3°)
AMounting outside (with fixed switching angle 3°)

(4)
withoutno assembly end stops
Nwith alignment aid
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • connector plug M 16 x 1.5, 10-pole, bottom
  • with fixed switching angle
  • Metal enclosure
  • Good resistance to oil and petroleum spirit
  • For left or right hinged doors
  • 141 mm x 115 mm x 21,5 mm
  • Simple mounting, suitable for all conventional profile systems (30 … 60 mm)

Ordering data

Note (Delivery capacity)

Not available!

Product type description

HINGED SAFETY SWITCHES TVS410ST4-11/11I

Article number (order number)

101184433

eCl@ss number, version 12.0

27-27-06-09

eCl@ss number, version 11.0

27-27-06-09

eCl@ss number, version 9.0

27-27-06-09

ETIM number, version 7.0

EC002591

ETIM number, version 6.0

EC002591

General data

Housing material

Metal, zinc die-cast

Colour of the housing

Black

Gross weight

640 g

General data - Features

Mounting inside

Yes

Number of auxiliary contacts

2

Number of safety contacts

2

Safety classification

Standards

BG-GS-ET-15

EN ISO 13849-1

EN IEC 60947-5-1

Mission time

20 Year(s)

Safety classification - Safety outputs

B10D Normally-closed contact (NC)

2,000,000 Operations

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Positive break angle

5 °

Opening angle

180°

Mechanical data - Connection technique

Termination

Connector plug M16, 10-pole, bottom

Connector M16

Mechanical data - Dimensions

Length of sensor

21.5 mm

Width of sensor

141 mm

Height of sensor

115 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

-25 ... +65 °C

Ambient conditions - Insulation values

Rated insulation voltage Ui

250 VAC

Rated impulse withstand voltage Uimp

2.5 kV

Electrical data

Thermal test current

2.5 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

NO contact, NC contact

Switching principle

Slow action

Maximum switching frequency

1,200 /h

Material of the contacts, electrical

Silver-nickel alloy 10

Note

Note (General)

Closed guard device = 0° in contact switch travel diagrams.

The factory-set switching angle is 3°.

Until the limit of the mechanical life has been reached the angle can increase up to 8° under normal wear-out conditions.

The positive break angle is 10°.

Switch travel diagram

Diagram


Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 2024-11-24, 2:04 p.m.