SEK103
SEK103
Downloads
Ordering data
Product type description |
SEK103 |
Article number (order number) |
101009594 |
EAN (European Article Number) |
4030661612584 |
eCl@ss number, version 12.0 |
27-27-26-01 |
eCl@ss number, version 11.0 |
27-27-26-01 |
eCl@ss number, version 9.0 |
27-27-26-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
|
cURus CCC |
General data
Standards |
EN 50047 DIN VDE 0660-200 EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
IEC 60068-2-30 |
Installation conditions (mechanical) |
arbitrarily |
Housing material |
Polyamide PA 66 GV, self-extinguishing, hardly flammable |
Gross weight |
69 g |
General data - Features
Number of normally closed (NC) |
1 |
Number of normally open (NO) |
1 |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
20,000,000 Operations |
B10D Normally open contact (NO) |
1,000,000 Operations |
Note (B10D Normally open contact (NO)) |
at 10% Ie and ohmic load |
B10D- Value Normally-closed contact/Normally open contact (NC/NO) |
20,000,000 Operations |
Mechanical data
Mechanical life, minimum |
30,000,000 Operations |
Actuating force |
10 N |
Positive break travel |
2 mm |
Note Bounce duration |
Bounce duration at an Actuating speed of 100mm/s |
Mechanical data - Connection technique
Termination |
Flat plug-in connector - 6.35 x 0.8 mm |
Ambient conditions
Ambient temperature |
-25 ... +80 °C |
Resistance to vibrations |
10 … 200 Hz, with 15 g |
Restistance to shock |
30 g / 18 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
2.5 kV |
Degree of pollution |
3 |
Electrical data
Thermal test current |
10 A |
Rated operating voltage |
400 VAC |
Utilisation category AC-15 |
8 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
5 A |
Suitable for low-voltages |
≥ 24 VDC / ≥ 10 mA |
Switching principle |
Slow action |
Bounce duration, maximum |
5 ms |
Maximum switching frequency |
3,600 /h |
Material of the contacts, electrical |
Gold-plated silver (AgNi 15 + Au 0,3µm) |
Electrical data - Contacts
Voltage, Utilisation category AC-15 |
250 VAC |
Language filter
Datasheet
UL Certificate
CCC certification
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | SEK |
Type: | See ordering code |
Description of the component: | Positive break position switch for safety functions or position switch without safety function |
Relevant Directives: | Machinery Directive 1) | 2006/42/EC |
Low Voltage Directive 2) | 2014/35/EU | |
RoHS-Directive | 2011/65/EU |
Affixing of the CE conformity mark: | 1) for safety components, whose type plate is labelled "safety component" 2) for position switches without safety function |
Applied standards: | DIN EN 60947-5-1:2010 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, November 6, 2017 |
Authorised signature Philip Schmersal Managing Director |
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.