ZSD6CC
ZSD6CC
Product type description: ZSD (1) |
(1) | |
215 | 3-stage grip switch |
6 | 3-stage door handle switch with additional push-button |
- Thermoplastic enclosure
- 1 Cable entry M 20 x 1.5
- Good resistance to oil and petroleum spirit
- Particularly fit for robot applications in accordance with the ANSI Robotics Standard
- The redundant contact configuration enables signal processing using conventional safety relay modules
- Contacts do not close upon reset (level 3 -> level 1)
Ordering data
Product type description |
ZSD6CC |
Article number (order number) |
103043704 |
EAN (European Article Number) |
4030661623368 |
eCl@ss number, version 12.0 |
27-37-12-38 |
eCl@ss number, version 11.0 |
27-37-12-38 |
eCl@ss number, version 9.0 |
27-37-12-38 |
ETIM number, version 7.0 |
EC002571 |
ETIM number, version 6.0 |
EC002571 |
Approvals - Standards
|
cULus |
General data
Standards |
EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-8 |
Housing material |
Plastic, thermoplastic, self-extinguishing |
Gross weight |
180 g |
General data - Features
Push button, additionally |
Yes |
Number of normally closed (NC) |
1 |
Number of normally open (NO) |
2 |
Safety classification |
Standards |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
d |
Category |
3 |
B10D Normally-closed contact (NC) |
100,000 Operations |
Mechanical data
Note (Mechanical life) |
NO: |
Positive break travel |
4.7 mm |
Positive break force, minimum |
70 N |
Mechanical data - Connection technique
Cable entry |
1 x M20 x 1,5 |
Termination |
Cage clamp |
Authorised cable section, minimum |
7 mm |
Authorised cable section, maximum |
13 mm |
Cable section, minimum |
0.2 mm² |
Cable section, maximum |
1.5 mm² |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
-10 ... +60 °C |
Storage and transport temperature |
-40 ... +80 °C |
Relative humidity, minimum |
45 % |
Relative humidity, maximum |
85 % |
Note (Relative humidity) |
non-condensing |
Resistance to vibrations |
Operation: 5 … 55 Hz, Amplitude 0,5 mm min./ Damage: 16,7 Hz, Amplitude 1,5 mm min. |
Restistance to shock |
Operation: 150 m/s², Damage: 1.000 m/s² |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
1.5 kV |
Electrical data
Rated operating voltage |
250 VAC |
Operating current |
2,500 mA |
External wire and device fuse rating |
10A f |
Switching element |
NO contact, NC contact NO contact / NC contact |
Switching principle |
Slow action |
Maximum switching frequency |
1,200 /h |
Material of the contacts, electrical |
Silver |
Electrical data - Contacts
Voltage, Utilisation category AC-15 |
125 VAC |
Current, Utilisation category AC-15 |
1.5 A |
Voltage, Utilisation category DC-13 |
125 VDC |
Current, Utilisation category DC-13 |
0.22 A |
Electrical data - Auxiliary contacts
Voltage, Utilisation category AC-15 |
125 VAC |
Current, Utilisation category AC-15 |
1 A |
Voltage, Utilisation category DC-13 |
125 VDC |
Current, Utilisation category DC-13 |
0.22 A |
Accessory
Recommended safety switchgear |
SRB, 2-channel with cross-wire detection |
Note
Note (General) |
Customer-specific versions, with connecting cable, are available upon request. The monitoring module must offer the possibility of cross-wire monitoring. Only a double shielded cable is authorised as supply line. 1) If the device is to be used in a damp room, a suitable connection cable must be used. 1) This device has been tested for impact and fire resistance according to UL508. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 2024-11-23, 3:37 p.m.