AST LC ST-AS
Archive
Item number:101182561


Product features
- AS-i connection, connector plug M12, 4-pole
- NOTICE: Not available!
- Input module for 2 monitored PNP semiconductor outputs for safety light curtains and light grids
- Thermoplastic enclosure
- AS-Interface LED and status display
- 86,5 mm x 28 mm x 28 mm
- Long life
- Integrated AS-Interface
Ordering data
Note (Delivery capacity)Not available!
Product type descriptionAST LC ST-AS
Article number (order number)101182561
EAN (European Article Number)4030661317649
eCl@ss number, version 12.027-24-26-04
eCl@ss number, version 11.027-24-26-04
eCl@ss number, version 9.027-24-26-04
ETIM number, version 7.0EC001599
ETIM number, version 6.0EC001599
Approvals - Standards
CertificatescULus
General data
StandardsEN 50295EN IEC 61496-1EN IEC 61508EN ISO 13849-1
Connector (electric)AS-i connection: connector plug M12, 4-pole
Housing materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Reaction time, maximum20ms
Gross weight185g
General data - Features
Cross-circuit detectionYes
Integral system diagnostics, statusYes
Number of pre-wired cable2
Safety classification
StandardsEN IEC 61508
Performance Level, up toe
Category4
PFH value1.74 x 10⁻⁹/h
Safety Integrity Level (SIL), suitable for applications in3
Mission time20Year(s)
Mechanical data - Dimensions
Diameter of sensor28mm
Height of sensor86.5mm
Ambient conditions
IP Degree of protectionIP67
Ambient temperature-25 ... +60 °C
Storage and transport temperature-25 ... +85 °C
Relative humidity, minimum30%
Relative humidity, maximum95%
Note (Relative humidity)non-condensing
Protection classII
Ambient conditions - Insulation values
Rated insulation voltage Ui32 VDC
Rated impulse withstand voltage Uimp0.8kV
Overvoltage categoryIII
Degree of pollution3
Electrical data
Current consumption50mA
Electrical data - AS Interface
Rated operating voltage26.5 ... 31.6 VDC (Protection against polarity reversal)
Electrical data - AS-Interface specification
AS-i Version V 2.1
AS-i Profile S-0.B.F.E
AS-i, IO-Code0x7
AS-i, ID-Code0xB
AS-i, ID-Code10xF
AS-i, ID-Code20xE
AS-i Input, Channel 1Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Outputs, DO 0 … DO 3No Function
AS-i Parameter bits, P0 ... P3No function
AS-i Parameter bits, P3Authorised operation canal 1 + 2
Note (AS-i Parameter bits)Set the parameter outputs to "1111" (0xF)
AS-i Input module address0
Note (AS-i Input module address)Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Status indication
Note (LED switching conditions display)(1) LED green: Supply voltage(2) LED red: Communication error(3) LED yellow: Enabling status OSSD 1/2
Pin assignment
ConnectionST1 male connector / power supply for Safety light grids and curtains
PIN 124 VDC
PIN 2n.c.
PIN 3GND
PIN 4n.c.
PIN 5FE (functional earth connection)
ConnectionST2 female connector / Safety light grids and curtains
PIN 1+ 24 VDC
PIN 2OSSD 1
PIN 3GND
PIN 4OSSD 2
PIN 5FE (functional earth connection)
Wiring example
Note (Wiring diagram)The emitter module has to be wired up separately Please observe the corresponding SLC/SLG documentation (test signal).The Opto-Tube is directly connected to the receiver module (ST2). The receiver module is supplied with 24 V DC via the connector (ST1).The Opto-Tube itself is connected via the M12 connector (ST) to the AS-i network. Before hand the module has to be programmed with an individual address (1 - 31).The wiring diagram shows an active optoelectronic device (AOPD) (type SLC/SLG 420) with a safety input module AST LC ST-AS (Opto-Tube) connected to the AS-i Safety at Work system.