SE-400 C EVALUATION UNIT

Item number: 101153920

Downloads

TraceParts CAD Data
ePLAN Data
CADENAS CAD Data
  • To monitor 1 safety edge(s)
  • 2 safety contacts, STOP 0
  • 1 Signalling output

Ordering data

Product type description

SE-400 C EVALUATION UNIT

Article number (order number)

101153920

EAN (European Article Number)

4030661289175

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

TÜV

cULus

General data

Standards

EN ISO 13849-1

EN ISO 13850

Climatic stress

EN ISO 13856-2

Housing material

Glass-fibre, thermoplastic

Reaction time, maximum

32 ms

Gross weight

184 g

General data - Features

Electronic Fuse

Yes

Wire breakage detection

Yes

Cross-circuit detection

Yes

Start input

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Reset edge detection

Yes

Reset after disconnection of supply voltage

Yes

Earth connection detection

Yes

Integral system diagnostics, status

Yes

Number of LEDs

2

Number of undelayed semi-conductor outputs with signaling function

1

Number of safety contacts

2

Number of signalling outputs

1

Safety classification

Performance Level, up to

e

Category

4

Control category to EN954

4

PFH value

2.47 x 10⁻⁸ /h

Note (PFH-value)

up to max. 50,000 switching cycles/year

Mission time

20 Year(s)

Stop-Category

0

Mechanical data

Mechanical life, minimum

30,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Length of cable

200 m

Termination

Screw terminals M20 x 1.5

Cable section, maximum

2 x 1.5 mm²

Note

All indications including the conductor ferrules.

Mechanical data - Dimensions

Width

22.5 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

+5 ... +55 °C

Resistance to vibrations

10 … 55 Hz, amplitude 0.15 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Operating voltage

24 VDC -10 % / +20 %

Rated operating voltage

24 VDC

Operating current

150 mA

Rated AC voltage for controls at DC minimum

21.6 VDC

Rated control voltage at DC, maximum

28.8 VDC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

2 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

3 A

Electrical power consumption, maximum

4 W

Time to readiness, maximum

32 ms

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Safety edge function

Other data

Note (applications)

Safety edges

Note

Note (General)

The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components.

If there it any risk whatsoever, the machine may not be restarted.

Wiring example

Note (Wiring diagram)

A Start-Reset-Taster (S) can optionally be connected to the feedback circuit.

Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3).

The wiring diagram is shown for the de-energised condition.

Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-400C up to PL e and Category 4.

The feedback circuit monitors the position of the contactors KA and KB.


Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 27/04/2024, 23:22