SLC 220-E/R0625-80-RFBM
SLC 220-E/R0625-80-RFBM
- Protection class IP65
- Safety type 2 in accordance with IEC 61496-1
- Resolution 30 and 80 mm
- Protection field height from 175 mm … 1675 mm
Ordering data
Note (Delivery capacity) |
Not available! |
Product type description |
SLC 220-E/R0625-80-RFBM |
Article number (order number) |
101206381 |
eCl@ss number, version 12.0 |
27-27-27-04 |
eCl@ss number, version 11.0 |
27-27-27-04 |
eCl@ss number, version 9.0 |
27-27-27-04 |
ETIM number, version 7.0 |
EC002549 |
ETIM number, version 6.0 |
EC002549 |
Approvals - Standards
|
cULus |
General data
Standards |
EN IEC 61496-2 EN IEC 61496-1 |
Master- or Slave-function |
master |
Housing material |
Aluminium |
Reaction time, maximum |
12 ms |
Gross weight |
1,900 g |
General data - Features
Cascadable |
Yes |
Restart interlock (manual reset) |
Yes |
Blanking function |
Yes |
Integral system diagnostics, status |
Yes |
Integral system diagnostics |
Yes |
Number of fail-safe digital outputs |
2 |
Number of beams |
8 |
Safety classification |
Standards |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
d |
Category |
2 |
PFH value |
3.59 x 10⁻⁷ /h |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
2 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s |
80 mm |
Height of the protection field |
625 mm |
Range, protection field, minimum |
0.3 m |
Range, protection field, maximum |
6 m |
Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
Termination |
Connector |
Terminal connector, Recipient |
Connector plug M12, 6-pole Connector plug M12, 8-pole |
Terminal, Connector, Transmitter |
Connector plug M12, 6-pole Connector plug M12, 8-pole |
Length of the connectable cable, maximum |
100 m |
Mechanical data - Dimensions
Diameter of sensor |
40 mm |
Height of sensor |
654 mm |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
-10 ... +50 °C |
Storage and transport temperature |
-20 ... +70 °C |
Protection class |
III |
Electrical data
Switching voltage OSSD, HIGH signal |
24 V |
Electrical power consumption of the receiver |
8 W |
Electrical power consumption of the transmitter |
4 W |
Cable length (Master/Slave), maximum |
3 m |
Electrical data - Safety digital outputs
Output current, (fail-safe output), maximum |
0.2 A |
Design of control elements |
p-type |
Scope of delivery
Scope of delivery |
Emitter + receiver, mounting angle |
Accessory
Recommended safety switchgear |
SCR 211 |
Note
Note (General) |
Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Contact arrangement
Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 25/11/2024, 11:04