ZQ 700 FK-AS
ZQ 700 FK-AS
- AS interface Connection for flat cable, bottom, can be rotated
- Thermoplastic enclosure
- One tension force for cable lengths up to 10 m
- Release push button
- Position indicator
- Twisting of towing eye not possible
- wire pull and breakage detection
- Double-insulated
- Integrated AS-Interface
- Suitable for AS-i Power24
Ordering data
Note (Delivery capacity) |
Not available! |
Product type description |
ZQ 700 FK-AS |
Article number (order number) |
101215845 |
EAN (European Article Number) |
4030661404677 |
eCl@ss number, version 12.0 |
27-37-12-01 |
eCl@ss number, version 11.0 |
27-37-12-01 |
eCl@ss number, version 9.0 |
27-37-12-01 |
ETIM number, version 7.0 |
EC002033 |
ETIM number, version 6.0 |
EC002033 |
Approvals - Standards
|
cULus ASi-SaW |
General data
Standards |
EN 50295 EN ISO 13849-1 EN ISO 13850 EN IEC 60947-5-1 EN IEC 61508 |
Housing material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the housing cover |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Length of the wire, maximum |
10 m |
Reaction time, maximum |
100 ms |
Gross weight |
265 g |
Safety classification |
Standards |
EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
1.40 x 10⁻⁸ /h |
Note (PFH-value) |
up to max. 5,000 switching cycles/year |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
100,000 Operations |
Actuating force, maximum |
200 N |
Actuating travel |
400 mm |
Mechanical data - Connection technique
Termination |
Connection for flat cable |
Mechanical data - Dimensions
Length of sensor |
51 mm |
Width of sensor |
40.5 mm |
Height of sensor |
182.5 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +60 °C |
Storage and transport temperature |
-25 ... +85 °C |
Relative humidity, minimum |
30 % |
Relative humidity, maximum |
95 % |
Note (Relative humidity) |
non-condensing non-icing |
Resistance to vibrations |
10 … 150 Hz, amplitude 0.35 mm / 5 g |
Restistance to shock |
15 g / 11 ms |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 V |
Rated impulse withstand voltage Uimp |
0.8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Current consumption |
50 mA |
Switching principle |
Snap action |
Maximum switching frequency |
3,600 /h |
Electrical data - AS Interface
Rated operating voltage |
18 ... 31.6 VDC (Protection against polarity reversal) |
Electrical data - AS-Interface specification
AS-i Version |
V 3.0 |
AS-i Profile |
S-0.B.F.F |
AS-i, IO-Code |
0x0 |
AS-i, ID-Code |
0xB |
AS-i, ID-Code1 |
0xF |
AS-i, ID-Code2 |
0xF |
AS-i Input, Channel 1 |
Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 |
Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 … DO 3 |
No Function |
AS-i Parameter bits, P0 |
Channel 2 switched |
AS-i Parameter bits, P1 |
No function |
AS-i Parameter bits, P2 |
No function |
AS-i Parameter bits, P3 |
No function |
Note (AS-i Parameter bits) |
Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address |
0 |
Note (AS-i Input module address) |
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Note
Note (General) |
Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. The addressing must take place via the M12 connector or the flat cable connection. At 2 mm to 5 mm distance, intermediate wire supports are required, see accessories |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
AS interface safety at work certificate
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Dimensional drawing basic component
Characteristic curve
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 01/12/2024, 4:57 am