AZM300B-I2-ST-AS-A

Item number: 103005906

Product type description:
AZM300(1)(2)-ST-AS-(3)(4)(5)

(1)
ZGuard locking monitored >
BActuator monitored

(2)
withoutStandard coding
I1Individual coding
I2Individual coding, multiple teaching

(3)
withoutPower to unlock
APower to lock

(4)
withoutMagnet supply from AS-Interface
PMagnet supply 24 VDC (AUX)

(5)
withoutManual release
NEmergency release
TEmergency exit
T8Emergency exit, distance 8.5 mm
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • Thermoplastic enclosure
  • Repeated individual coding with RFID technology
  • Coding level "High" according to ISO 14119
  • Suitable for hinged and sliding guards
  • 3 different directions of actuation
  • Actuator monitored
  • Power to lock
  • Magnet supply through the AS-Interface
  • hygienic design
  • Protection class IP 69
  • Solenoid interlock with integrated AS-i Safety Interface
  • Universal repeatedly teachable or individual coding because of the RFID technology
  • I-variants with coding level HIGH to ISO 14119
  • 2 integrated snap-in stages

Ordering data

Product type description

AZM300B-I2-ST-AS-A

Article number (order number)

103005906

EAN (European Article Number)

4030661475073

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

ASi-SaW

ECOLAB

EAC

FCC

General data

Standards

EN IEC 62026-2

EN ISO 13849-1

EN ISO 14119

EN IEC 60947-5-1

EN IEC 61508

Coding

Individual coding, multiple teaching

Coding level according to EN ISO 14119

High

Working principle

RFID

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

622 g

Time to readiness, maximum

5,000 ms

Reaction time, maximum

120 ms

Duration of risk, maximum

200 ms

General data - Features

Power to lock

Yes

Actuator monitored

Yes

Latching

Yes

Manual release

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of actuating directions

3

Safety classification

Standards

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

4.00 x 10⁻¹⁰ /h

PFD value

7.00 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)

Holding force

1,150 N

Latching force, adjustable, position 1

25 N

Latching force, adjustable, position 2

50 N

Mechanical data - Switching distances according EN IEC 60947-5-3

Assured switching distance "ON" Sao

1 mm

Assured switching distance "OFF" Sar

20 mm

Switch distance, typical

2 mm

Mechanical data - Connection technique

Termination

Connector plug M12, 4-pole, (A-coding)

Mechanical data - Dimensions

Length of sensor

34.4 mm

Width of sensor

87.4 mm

Height of sensor

102.6 mm

Ambient conditions

Degree of protection

IP67

IP69K

IP66

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-10 °C

Storage and transport temperature, maximum

+90 °C

Resistance to vibrations

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data - AS Interface

AS-i Operating voltage, minimum

26.5 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

AS-i Current consumption, maximum

200 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 3.0

AS-i Profile

S-7.B.F.E

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0

Solenoid control

AS-i Outputs, DO 1

No Function

AS-i Outputs, DO 2

No Function

AS-i Outputs, DO 3

No Function

AS-i Parameter bits, P0

Safety guard closed and can be locked

AS-i Parameter bits, P1

Solenoid interlock locked

AS-i Parameter bits, P2

Auxiliary voltage in

AS-i Parameter bits, P3

Internal device error (FID)

Note (AS-i Parameter bits)

Set the parameter outputs to "1111" (0xF)

FID: periphery error

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Status indication

Note (LED switching conditions display)

(1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active

(2) LED yellow: Device condition (Enabling status)

(3) LED red: Internal device error

Pin assignment

PIN 1

AS-Interface +

PIN 2

Aux - (P)

PIN 3

AS-Interface -

PIN 4

Aux + (P)

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

AZ/AZM300-B1


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 08/12/2022, 02:02