DHS-U1-BKWH-L5-5.00-LT
DHS-U1-BKWH-L5-5.00-LT
- With illuminated pushbutton
- Connecting cable, 5-core, 5 m
- Protection class IP65 / IP67
- Machine status directly recognisable on the door handle
- Door handle in an ergonomical design
- Can be combined with solenoid interlock AZM40 or safety sensor RSS260
- Can also be used without safety switchgear device
- For left or right hinged safety guards
Ordering data
Product type description |
DHS-U1-BKWH-L5-5.00-LT |
Article number (order number) |
103053688 |
EAN (European Article Number) |
4030661640471 |
eCl@ss number, version 12.0 |
27-33-01-90 |
eCl@ss number, version 11.0 |
27-33-01-90 |
eCl@ss number, version 9.0 |
27-33-01-90 |
ETIM number, version 7.0 |
EC000229 |
ETIM number, version 6.0 |
EC000229 |
Approvals - Standards
|
cULus |
General data
Standards |
EN IEC 60947-5-1 |
|
Housing material |
Glass-fibre, reinforced thermoplastic |
|
Material of the handle |
translucent PMMA |
|
Gross weight |
575 g |
|
Material of the holder |
Glass-fibre, reinforced thermoplastic |
|
|
Yellow Blue Green Red White |
General data - Features
Idle assignable pushbutton |
Yes |
Mechanical data
Mechanical life, Command devices |
1,000,000 Operations |
|
Actuating stroke |
1 mm |
|
Actuating force, maximum |
10 N |
|
Note Bounce duration |
Bounce duration at an Actuating speed of 100mm/s |
|
Type of the fixing screws |
2x M6 |
|
Tightening torque of the screw |
3.5 Nm |
|
|
10 N |
|
Type of mounting screws for the handle body |
2x Torx Plus T20x25 |
|
Tightening torque of mounting screws for the handle body |
2.5 Nm |
Mechanical data - Connection technique
Length of cable |
5 m |
Termination |
Connecting cable, 5 pole |
Wire cross-section |
0.2 mm2 |
Cable diameter |
5.5 mm |
Bending radius (fixed) |
5 x Ø-cable |
Bending radius (repeated) |
10 x Ø-cable |
Wire cross-section |
24 AWG |
Material of the Cable mantle |
PUR |
Mechanical data - Dimensions
Length |
202 mm |
Width |
40 mm |
Height |
84 mm |
Ambient conditions
Degree of protection |
IP66 IP67 |
Relative humidity, maximum |
93 % |
Note (Relative humidity) |
non-condensing non-icing |
Resistance to vibrations |
10 … 150 Hz, amplitude 0.35 mm (EN 60947-5-2) |
Restistance to shock |
30 g / 11 ms (EN 60947-5-2) |
Protection class |
III |
Permissible installation altitude above sea level, maximum |
3,000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0.8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Current consumption inidcator lamp |
30 mA |
Rated operating voltage |
24 VDC |
Operating current |
150 mA |
Required rated short-circuit current |
100 A |
Utilisation category DC-12 |
24 VDC |
Utilisation category DC-12 |
0.03 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
0.03 A |
External wire and device fuse rating |
2 A gG |
Bounce duration, maximum |
2 ms |
Maximum switching frequency |
1,000 /h |
Pin assignment
PIN 1 |
24 VDC: brown |
PIN 2 |
Normally open contact (illuminated button): white (WH) |
PIN 3 |
GND: Blue |
PIN 4 |
Input LED (in illuminated button): black (BK) |
PIN 5 |
n.c.: red (RD) or grey (GY) |
Scope of delivery
Scope of delivery |
The push button caps (blue, green, red, white, yellow) are included in the scope of delivery. |
Note (scope of delivery, number and type) |
The insert for use with the safety sensor RSS260 or without integrated actuator must be ordered separately. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
Brochure
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | DHS-U1 |
Type: | See ordering code |
Description of the component: | Door handle system |
Relevant Directives: | EMC-Directive | 2014/30/EU |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-1:2017 + AC:2020 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, May 21, 2024 |
Authorised signature Philip Schmersal Managing Director |
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 30/12/2024, 04:40