EX-BNS 33-02ZG-2187-3G/D 5,0M
EX-BNS 33-02ZG-2187-3G/D 5,0M
- Individual contact outlet
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- 88 mm x 25 mm x 13 mm
- Concealed mounting possible
- Insensitive to transverse misalignment
- no mechanical wear
Ordering data
| Product type description |
EX-BNS 33-02ZG-2187-3G/D 5,0M |
| Article number (order number) |
101192970 |
| EAN (European Article Number) |
4030661354415 |
| eCl@ss number, version 12.0 |
27-27-44-01 |
| eCl@ss number, version 11.0 |
27-27-24-02 |
| eCl@ss number, version 9.0 |
27-27-24-02 |
| ETIM number, version 7.0 |
EC002544 |
| ETIM number, version 6.0 |
EC002544 |
Approvals - Standards
| Certificates |
ATEX (Konformitätserklärung) |
Explosion protection
| Explosion protection: regulations |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
| Explosion protection zones |
2 22 |
| Explosion protection category |
3G 3D |
| Explosion protection designation |
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
| Manufacturer declaration |
ATEX Zone 2 and 22 |
General data
| Housing construction form |
Block |
| Installation conditions (mechanical) |
not flush |
| Housing material |
Glass-fibre, reinforced thermoplastic |
| Gross weight |
203 g |
General data - Features
| Coding |
Yes |
| Short circuit detection |
Yes |
| Cross-circuit detection |
Yes |
| Integral system diagnostics, status |
Yes |
| Prerequisite evaluation unit |
Yes |
| Number of normally closed (NC) |
2 |
| Safety classification |
| Standards |
EN ISO 13849-1 |
| Mission time |
20 Year(s) |
Safety classification - Safety outputs
| B10D Normally-closed contact (NC) |
25,000,000 Operations |
| B10D- Value Normally-closed contact/Normally open contact (NC/NO) |
25,000,000 Operations |
Mechanical data
| Active area |
lateral |
| Actuating element |
Magnet |
| Impact energy, maximum |
1 J |
| Direction of motion |
Head-on to the active surface |
Mechanical data - Switching distances
| Assured switching distance "ON" Sao |
5 mm |
| Assured switching distance "OFF" Sar |
15 mm |
| Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
| Note (Repeat accuracy R) |
Repeat accuracy R ≤ 0,1 x Sao |
Mechanical data - Connection technique
| Length of cable |
5 m |
| Termination |
cable |
| Number of cable wires |
4 |
| Wire cross-section |
0.25 mm2 |
| Wire cross-section |
23 AWG |
| Material of the Cable mantle |
PVC |
Mechanical data - Dimensions
| Length of sensor |
13 mm |
| Width of sensor |
88 mm |
| Height of sensor |
25 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
| Restistance to shock |
30 g / 11 ms |
Electrical data
| Switching voltage, maximum |
24 VDC |
| Switching current, maximum |
0.01 A |
| Switching capacity, maximum |
0.24 W |
| Switching element |
2 NC contact |
| Switching principle |
Reed contacts, Non-contact principle |
| Switching frequency, maximum |
5 Hz |
Status indication
| Note (Integral System Diagnostics, status ) |
The LED is illuminated when the guard door is open. |
Scope of delivery
| Scope of delivery |
Actuator must be ordered separately. |
Accessory
| Recommendation (actuator) |
EX-BPS 33-3G/D |
Note
| Note (General) |
Contact symbols shown for the closed condition of the guard device. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kxbns3f08
| 130.9 kB | .jpg | 352.778 x 113.594 mm - 1000 x 322 px - 72 dpi
| 18.1 kB | .png | 74.083 x 23.989 mm - 210 x 68 px - 72 dpi
| 18.0 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 1.3 MB | .png | 101.6 x 32.766 mm - 2000 x 645 px - 500 dpi
| 23.2 kB | .jpg | 123.472 x 39.864 mm - 350 x 113 px - 72 dpi
Dimensional drawing basic component
Diagram
Characteristic curve
103050108 EX-BNS 33-02ZG-2187-3GD 5M
- Individual contact outlet
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- 88 mm x 25 mm x 13 mm
- Concealed mounting possible
- Insensitive to transverse misalignment
- no mechanical wear
| EU Declaration of Conformity | ![]() |
| Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
| Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
| Name of the component: | EX-BNS 33-...-3GD | EX-BPS 33-3GD |
| Type: | See ordering code |
| Marking: | D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X | Ex h IIC T6 Gc Ex h IIIC T80°C Dc |
| Description of the component: | Coded safety-sensor with magnetic operating principle in combination with the SRB(-E) / PROTECT-SELECT / PSC1 safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the EN 60947-5-3. |
| Relevant Directives: | Machinery Directive | 2006/42/EC |
| Explosion Protection Directive (ATEX) | 2014/34/EU | |
| RoHS-Directive | 2011/65/EU |
| Applied standards: | EN 60947-5-3:2013 EN IEC 60079-0:2018 + AC:2020 EN IEC 60079-15:2019 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
| Notified body, which approved the full quality assurance system, referred to Appendix IV, 2014/34/EU: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
| Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
| Conformity with the explosion protection directive 2014/34/EU (ATEX) is declared by the manufacturer without involving a test center. |
| Place and date of issue: | Wuppertal, June 1, 2025 |
![]() |
| Authorised signature Philip Schmersal Managing Director |
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 13/02/2026, 22:49

