PSC1-C-10-SDM1-FB1
PSC1-C-10-SDM1-FB1
- Memory card
- conversion of the field bus protocols by software
- integrated SD-Bus-Gateway
- Safe drive monitoring according to EN 61800-5-2 (SDM – Safe Drive Monitoring) for 1 axis
- Modular expansion with up to 64 inputs / outputs
- 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switching semiconductor outputs
- 14 safe inputs on the base module
- 2 Signalling outputs
- 2 safety relay contacts
Ordering data
Product type description |
PSC1-C-10-SDM1-FB1 |
Article number (order number) |
103008445 |
EAN (European Article Number) |
4030661455068 |
eCl@ss number, version 12.0 |
27-24-22-07 |
eCl@ss number, version 11.0 |
27-24-22-07 |
eCl@ss number, version 9.0 |
27-24-22-07 |
ETIM number, version 7.0 |
EC000236 |
ETIM number, version 6.0 |
EC000236 |
Approvals - Standards
|
TÜV cULus |
General data
Gross weight |
593 g |
General data - Features
SD Card Slot |
Yes |
Master-Slave-Communication (decentralized) |
Yes |
Master-Master-Kommunikation |
Yes |
Integrated SD gateway |
Yes |
Number of pulse outputs (test pulse output) |
2 |
Number of relay outputs (1-channel) |
2 |
Number of digital fail-safe inputs |
14 |
Number of fail-safe digital outputs |
4 |
Number of signalling outputs |
2 |
Anzahl der Erweiterungsbaugruppen, maximal |
2 |
Safety classification |
Performance Level, up to |
e |
Category |
4 |
PFH value |
1.26 x 10⁻⁸ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data
Mounting |
can be clipped into standard rail |
Mechanical data - Connection technique
Cable section, minimum |
0.2 mm² |
Cable section, maximum |
2.5 mm² |
Wire cross-section, minimum |
24 AWG |
Wire cross-section, maximum |
12 AWG |
Wire cross-section |
24 ... 12 AWG |
Terminal (mechanical) |
Removable screw terminals |
Mechanical data - Dimensions
Width |
67.5 mm |
Height |
100 mm |
Depth |
115 mm |
Ambient conditions
Degree of protection |
IP20 |
Ambient temperature |
+0 ... +50 °C |
Storage and transport temperature |
-25 ... +70 °C |
Relative humidity, minimum |
5 % |
Relative humidity, maximum |
85 % |
Note (Relative humidity) |
non-condensing |
Permissible installation altitude above sea level, maximum |
2,000 m |
Ambient conditions - Insulation values
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Operating voltage |
24 VDC -15 % / +20 % |
Rated operating voltage |
24 VDC |
Electrical data - Universal communication interface
Designation, Communication interface |
RJ45 |
Electrical data - Communication protocols
Feldbus Protokoll |
EtherCAT EtherNet IP PROFINET IO |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) |
2,000 mA |
Design of control elements |
short-circuit proof, p-type (Q2 und Q3) |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
2 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
Electromagnetic compatibility |
DIN EN 62061 DIN EN 61800-3 |
Interfering radiation |
DIN EN 61000-6-4 |
EMC rating |
DIN EN 61000-6-7 DIN EN 61326-3 DIN EN 61000-6-2 |
Scope of delivery
Scope of delivery |
Backplane bus connector Connector terminals |
Electrical data - Spindle monitoring
Number of axis monitoring, max. |
1 |
Drive monitoring, encoder typ |
SSI TTL SINCOS Proximity switch |
Language filter
Datasheet
Software manual
Field bus communication manual
Installation manual
TÜV certification
UL Certificate
Device description files
Configuration software (document with link)
Software (Download)
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Video ID: SD-Interface-Mr-Safety
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | PSC1 |
Type: | See ordering code |
Description of the component: | Safety compact controller, with or without drive monitoring; IO expansion module, with or without relay expansion |
Relevant Directives: | Machinery Directive | 2006/42/EC |
EMC-Directive | 2014/30/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 61800-5-2:2017 EN ISO 13849-1:2015 EN 61508 parts 1-7:2010 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Notified body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
EC-Type Examination Certificate: | 01/205/5526.01/21 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Ort und Datum der Ausstellung: | Wuppertal, August 25, 2023 |
Authorised signature Philip Schmersal Managing Director |
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 14/11/2024, 19:23