EX-AZM300Z-I2-ST-1P2P-A-CR-3GD
EX-AZM300Z-I2-ST-1P2P-A-CR-3GD
Produkt-Typbezeichnung: EX-AZM300(1)(2)-ST(3)(4)(5) |
(1) | |
Z | Zuhaltungsüberwachung > |
B | Betätigerüberwachung |
(2) | |
ohne | Standardcodierung |
I1 | Individuelle Codierung |
I2 | Individuelle Codierung, mehrfach anlernbar |
(3) | |
1P2P | 1 Diagnoseausgang, p-schaltend und 2 Sicherheitsausgänge, p-schaltend |
SD2P | Serieller Diagnoseausgang und 2 Sicherheitsausgänge, p-schaltend |
(4) | |
ohne | Ruhestromprinzip |
A | Arbeitsstromprinzip |
(5) | |
CL | Mit Schutzgehäuse, Türanschlag links |
CR | Mit Schutzgehäuse, Türanschlag rechts |
- Explosion protection for ATEX Zones 2 and 22
- RFID-technology for needs-based protection against tampering
- Thermoplastic enclosure
- Suitable for mounting to profile systems
- Suitable for hinged and sliding guards
- Series-wiring
- Manual release
Ordering data
Product type description |
EX-AZM300Z-I2-ST-1P2P-A-CR-3GD |
Article number (order number) |
103052212 |
EAN (European Article Number) |
4030661632865 |
eCl@ss number, version 12.0 |
27-27-26-03 |
eCl@ss number, version 11.0 |
27-27-26-03 |
eCl@ss number, version 9.0 |
27-27-26-03 |
ETIM number, version 7.0 |
EC002593 |
ETIM number, version 6.0 |
EC002593 |
Approvals - Standards
Certificates |
ATEX (Konformitätserklärung) |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-7 EN 60079-31 |
Explosion protection zones |
2 22 |
Explosion protection category |
3G 3D |
Explosion protection designation |
D II 3G Ex ic IIC T5 Gc X D II 3D Ex tc IIIB T95°C Dc X |
General data
Standards |
EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding |
Individuelle Codierung, mehrfach anlernbar |
Coding level according to EN ISO 14119 |
hoch |
Working principle |
RFID |
Frequency band RFID |
125 kHz |
Transmitter output RFID, maximum |
-6 dB/m |
Housing material |
Kunststoff, glasfaserverstärkter Thermoplast, selbstverlöschend |
Duration of risk, maximum |
200 ms |
Reaction time, switching off safety outputs via actuator, maximum |
100 ms |
Reaction time, switching off safety outputs via safety inputs, maximum |
1,5 ms |
Gross weight |
1.100 g |
General data - Features
Power to lock |
Ja |
Solenoid interlock monitored |
Ja |
Latching |
Ja |
Manual release |
Ja |
Short circuit detection |
Ja |
Cross-circuit detection |
Ja |
Series-wiring |
Ja |
Safety functions |
Ja |
Integral system diagnostics, status |
Ja |
Number of actuating directions |
1 |
Number of fail-safe digital outputs |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Safety classification - Interlocking function
Performance Level, up to |
e |
Category |
4 |
PFH value |
5,20 x 10⁻¹⁰ /h |
PFD value |
4,50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety classification - Guard locking function
Performance Level, up to |
d |
Category |
2 |
PFH value |
2,00 x 10⁻⁹ /h |
PFD value |
1,80 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
1.000.000 Operations |
Note (Mechanical life) |
Bei Verwendung als Türanschlag: ≥ 50.000 Schaltspiele (Türmassen ≤ 5 kg und Betätigungsgeschwindigkeit ≤ 0,5 m/s) |
Angular misalignment between solenoid interlock and actuator, maximum |
2 ° |
Energy impact (protective case), maximum |
7 J |
Note (Energy impact) |
mit Edelstahlschutzgehäuse CL/CR |
Holding force FZh in accordance with EN ISO 14119 |
1.150 N |
Holding force Fmax, maximum |
1.500 N |
Latching force, adjustable, position 1 |
25 N |
Latching force, adjustable, position 2 |
50 N |
Type of the fixing screws |
2x M6 |
Note (Type of the fixing screws) |
Festigkeitsklasse min. 8.8 |
Tightening torque of the fixing screws, maximum |
8 Nm |
Material of the fixing screws |
Edelstahl (V4A) |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switch distance, typical |
2 mm |
Assured switching distance "ON" Sao |
1 mm |
Assured switching distance "OFF" Sar |
20 mm |
Mechanical data - Connection technique
Length of sensor chain, maximum |
200 m |
Note (length of the sensor chain) |
Leitungslänge und Leitungsquerschnitt verändern den Spannungsfall in Abhängigkeit vom Ausgangsstrom |
Note (series-wiring) |
Anzahl der Geräte unbegrenzt, externen Leitungsschutz beachten, max. 31 Geräte bei serieller Diagnose SD |
Termination |
Steckverbinder M12, 8-polig, A-codiert |
Mechanical data - Dimensions
Length of sensor |
178 mm |
Width of sensor |
93 mm |
Height of sensor |
40,3 mm |
Ambient conditions
Degree of protection |
IP66 IP67 IP69 |
Ambient temperature |
+0 ... +50 °C |
Storage and transport temperature |
-10 ... +90 °C |
Relative humidity, maximum |
93 % |
Note (Relative humidity) |
nicht kondensierend nicht vereisend |
Resistance to vibrations |
10 … 150 Hz, Amplitude 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
III |
Permissible installation altitude above sea level, maximum |
2.000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % (stabilisiertes PELV-Netzteil) |
No-load supply current I0, typical |
100 mA |
Current consumption with magnet ON, average |
200 mA |
Current consumption with magnet ON, peak |
350 mA / 200 ms |
Rated operating voltage |
24 VDC |
Required rated short-circuit current |
100 A |
External wire and device fuse rating |
2A gG |
Time to readiness, maximum |
5.000 ms |
Switching frequency, maximum |
0,5 Hz |
Utilisation category DC-12 |
24 VDC / 0,05 A |
Electrical fuse rating, maximum |
2 A |
Electrical data - Magnet control
Designation, Magnet control |
IN |
Switching thresholds |
-3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V |
10 mA |
Magnet switch-on time |
100 % |
Test pulse duration, maximum |
5 ms |
Test pulse interval, minimum |
40 ms |
Classification ZVEI CB24I, Sink |
C0 |
Classification ZVEI CB24I, Source |
C1 C2 C3 |
Electrical data - Safety digital inputs
Designation, Safety inputs |
X1 und X2 |
Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V |
5 mA |
Test pulse duration, maximum |
1 ms |
Test pulse interval, minimum |
100 ms |
Classification ZVEI CB24I, Sink |
C1 |
Classification ZVEI CB24I, Source |
C1 C2 C3 |
Electrical data - Safety digital outputs
Designation, Safety outputs |
Y1 und Y2 |
Design of control elements |
kurzschlussfest, p-schaltend |
Voltage drop Ud, maximum |
2 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,25 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,25 A |
Test pulse interval, typical |
1000 ms |
Test pulse duration, maximum |
0,5 ms |
Classification ZVEI CB24I, Source |
C2 |
Classification ZVEI CB24I, Sink |
C1 C2 |
Electrical data - Diagnostic outputs
Designation, Diagnostic outputs |
OUT |
Design of control elements |
kurzschlussfest, p-schaltend |
Voltage drop Ud, maximum |
2 V |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,05 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,05 A |
Status indication
Note (LED switching conditions display) |
Betriebszustand: gelbe LED Fehler Funktionsstörung: rote LED Versorgungsspannung UB: grüne LED |
Pin assignment
PIN 1 |
A1 Versorgungsspannung Ub |
PIN 2 |
X1 Sicherheitseingang 1 |
PIN 3 |
A2 GND |
PIN 4 |
Y1 Sicherheitsausgang 1 |
PIN 5 |
OUT Diagnoseausgang |
PIN 6 |
X2 Sicherheitseingang 2 |
PIN 7 |
Y2 Sicherheitsausgang 2 |
PIN 8 |
IN Magnetansteuerung |
Scope of delivery
Scope of delivery |
Der Betätiger ist nicht im Lieferumfang enthalten. |
Accessory
Recommendation (actuator) |
EX-AZ/AZM300-B1 |
Note
Note (General) |
Für Türen, die bündig mit dem Türrahmen abschließen, kann die optionale Montageplatte MP-AZ/AZM300-1 verwendet werden. Für Glas- und Makrolontüren kann der optionale Montagesatz MS-AZ/AZM300-B1-1 verwendet werden. Die entsperrte Schutzeinrichtung kann, solange die Betätigereinheit in der Sicherheitszuhaltung eingeführt bleibt, wieder gesperrt werden. Die Sicherheitsausgänge werden erneut eingeschaltet, somit ist ein Öffnen der Schutzeinrichtung nicht erforderlich. |
Sprachfilter
Datenblatt
Betriebsanleitung und Konformitätserklärung
UKCA Konformitätserklärung
SISTEMA-VDMA Bibliothek/Library
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.
Generiert am: 28.03.2025, 04:58