schmersal_s_icon.png

RSS260-I2-SD-ST

Codice prodotto: 103003603

Product type description:

RSS260-(1)-(2)-(3)-(4)-(5)


(1)
withoutStandard coding
I1Individual coding
I2Individual coding, multiple teaching

(2)
DWith diagnostic output
SDWith serial diagnostic function 1)

(3)
withoutStandard version without feedback circuit monitoring EDM (External Device Monitoring)
F0EDM with automatic reset 1)
F1EDM with manual reset 1)

(4)
withoutWithout EMERGENCY STOP
QAcknowledge input error with EMERGENCY STOP 1)

(5)
withoutConnecting cable (lenght in m)
STConnector plug M8, 8-pole
LSTM12-8-0,25MCable 0.25 m long with connector M12, 8-pole
LSTM8-8-0,1MCable 0.1 m long with connector M8, 8-pole
LSTM12-5-0.25MCable 0.25 m long with connector M12, 5-pole

(*)
1)only for versions -ST, -LSTM12-8-0.25M and -LSTM8-8-0.1M
Non tutte le varianti del dispositivo possibili in base a questo codice prodotto sono disponibili e/o tecnicamente applicabili.
  • Repeated individual coding with RFID technology
  • Coding level "High" according to ISO 14119
  • 1 x connector plug M8
  • Frontal and lateral actuation enabled
  • Max. 31 sensors can be wired in series.
  • Thermoplastic enclosure
  • Simple mounting without additional angle
  • RFID-technology for needs-based protection against tampering

Ordering data

Product type description

RSS260-I2-SD-ST

Article number (order number)

103003603

EAN (European Article Number)

4030661436463

eCl@ss number, version 12.0

27-27-46-01

eCl@ss number, version 11.0

27-27-24-03

eCl@ss number, version 9.0

27-27-24-03

ETIM number, version 7.0

EC001829

ETIM number, version 6.0

EC001829

Approvals - Standards

Certificates

TÜV

cULus

FCC

IC

ANATEL

General data

Standards

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Coding

Codifica individuale, Teach-in ripetibile

Coding level according to EN ISO 14119

alto

Working principle

RFID

Frequency band RFID

125 kHz

Transmitter output RFID, maximum

-6 dB/m

Housing construction form

parallelepipedo

Installation conditions (mechanical)

non allineato

Sensor topology

Sensore per azionamento in serie

Housing material

Plastica, termoplastica, autoestinguente

Active area

materiale sintetico, termoplastica

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

Reaction time, switching off safety outputs via actuator, maximum

100 ms

Gross weight

60 g

General data - Features

Serial diagnostics

Short circuit detection

Cross-circuit detection

Series-wiring

Safety functions

Cascadable

Integral system diagnostics, status

Number of LEDs

3

Number of poles

8

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

31

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

6,80 x 10⁻¹⁰ /h

PFD value

1,20 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Actuating panels

lateralmente

lato frontale

Active area

lateralmente

davanti

Mounting

Per il montaggio dei sensori sono sufficienti viti comuni lunghe 20 mm. In caso di utilizzo delle piastre di montaggio si raccomanda l'uso di viti lunghe 25 mm.

Type of the fixing screws

2x M4

Tightening torque of the fixing screws, maximum

0,8 Nm

Mechanical data - Switching distances

Typical switching distance, frontal

12 mm

Typical switching distance, lateral

9 mm

Assured switching distance "ON", frontal

10 mm

Assured switching distance "OFF", frontal

18 mm

Assured switching distance "ON", lateral

6 mm

Assured switching distance "OFF", lateral

15 mm

Note (Sao)

The specifications of the safety switching distance Sao refer to a temperature range of
-10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-3

Spostamento assiale È tollerato un disallineamento orizzontale e verticale tra sensore di sicurezza e azionatore. Il disallineamento ammissibile dipende dalla distanza delle superfici attive di sensore e azionatore. All'interno del campo di tolleranza il sensore è attivabile.

Hysteresis (Switching distance), maximum

2 mm

Repeat accuracy R

0,5 mm

Note (Repeat accuracy R)

Spostamento assiale laterale: La superficie laterale lunga permette un disallineamento in altezza massimo (x) tra sensore ed azionatore di 8 mm (ad es. tolleranza di montaggio o per abbassamento della porta di sicurezza). Lo scostamento trasversale (Y) è pari a max. ± 18 mm (vedi figura: Funzionamento).Distanza minima fra due sistemi di sensori 100 mm

Mechanical data - Connection technique

Note (length of the sensor chain)

Cable length and cross-section change the voltage drop dependiing on the output current

Note (series-wiring)

Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Termination

Connettore M8, 8 poli

Mechanical data - Dimensions

Length of sensor

29,5 mm

Width of sensor

39,2 mm

Height of sensor

18 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-28 ... +65 °C

Storage and transport temperature

-28 ... +85 °C

Relative humidity, maximum

93 %

Note (Relative humidity)

non condensante

non gela

Resistance to vibrations

10…55 Hz, ampiezza 1 mm

Restistance to shock

30 g / 11 ms

Permissible installation altitude above sea level, maximum

2.000 m

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

Operating current, minimum

0,5 mA

No-load supply current I0, typical

35 mA

Rated operating voltage

24 VDC

Operating current

600 mA

Required rated short-circuit current

100 A

Time to readiness, maximum

2.000 ms

Switching frequency, maximum

1 Hz

Electrical fuse rating, maximum

2 A

Electrical data - Safety digital inputs

Designation, Safety inputs

X1 and X2

Current consumption of the safety inputs

5 mA

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

100 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Designation, Safety outputs

Y1 e Y2

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0,25 A

Design of control elements

resistente a cortocircuito, con commutazione p

Voltage drop Ud, maximum

1 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,25 A

Test pulse interval, typical

1000 ms

Test pulse duration, maximum

1 ms

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Serial diagnostic SD

Designation, Serial diagnostic SD

OUT

Operation current

150 mA

Design of control elements

short-circuit proof

Wiring capacitance

50 nF

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

Status indication

Note (LED switching conditions display)

LED giallo: Stato operativo

LED verde: Tensione di alimentazione

LED rosso: Errore

Pin assignment

PIN 1

A1 Ue: Bianco

PIN 2

X1 Ingresso di sicurezza 1: Marrone

PIN 3

A2 GND: Verde

PIN 4

Y1 Uscita di sicurezza 1: Giallo

PIN 5

uscita diagnostica seriale OUT grigio

PIN 6

X2 Ingresso di sicurezza 2: Rosa

PIN 7

Y2 Uscita di sicurezza 2: Blu

PIN 8

IN ingresso diagnostico seriale Rosa

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Accessory

Recommendation (actuator)

RST16-1

RST-U-2

RST260-1

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Note

Note (General)

Requisiti per la valorizzazione: ingresso di sicurezza a due canali, idoneo per sensori a commutazione p (positiva) con funzione NA. Il modulo di controllo deve supportare il test di funzione dei sensori di sicurezza con disattivazione ciclica delle uscite del sensore per max. 0,5 ms. Non è invece richiesta la funzione di rilevamento cortocircuito.

Filtro lingua

Download dell'ultima versione di Adobe Reader

Video ID: RSS-260-01

Basic function (Vimeo)


Video ID: RSS-260-02

Variable mounting options (Vimeo)


Video ID: RSS-260-03

Single device connection (Vimeo)


Video ID: RSS-260-04

Series connection with serial diagnostics (Vimeo)


Video ID: RSS-260-05

Cross-fault with controlled shut-down process (Vimeo)


Video ID: RSS-260-06

Tolerance to misalignment (Vimeo)


Video ID: RSS-260-07

Warning when actuator is in limit range (Vimeo)


Video ID: RSS-260-08

Teaching process for individual coding: RSS260-I (Vimeo)


Video ID: RSS-260-10

Teaching of a replacement actuator to RSS260-I2 (Vimeo)


Video ID: RSS-260-11

RST-16-1 actuator on flat contour safety guards (Vimeo)


Video ID: RSS-260-12

RST-U-2 actuator for confined spaces (Vimeo)


Video ID: RSS260-13

Produktinformation RSS260 (Vimeo)


Video ID: SD-Interface-Mr-Safety

ID: SD-Interface-Mr-Safety

| 75,0 MB | .mp4

| 70,0 MB | .mp4

EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:RSS260
Type:See ordering code
Description of the component:Non-contact safety sensor
Relevant Directives:Machinery Directive2006/42/EC
 RED-Directive2014/53/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 60947-5-3:2013
EN 300 330 V2.1.1:2017
EN ISO 14119:2013
EN ISO 13849-1:2023
EN 61508 parts 1-7:2010
Notified body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
EC-Type Examination Certificate:01/205/5348.04/25
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, January 9, 2025
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director
UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:RSS260
Type:See ordering code
Description of the component:Non-contact safety sensor
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Radio Equipment Regulations2017
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:



EN 60947-5-3:2013
EN 300 330 V2.1.1:2017
EN ISO 14119:2013
EN ISO 13849-1:2015
IEC 61508 parts 1-7:2010
Approved body for Type Examination:TÜV Rheinland UK Ltd.
1011 Stratford Road
Solihull, B90 4BN
ID: 2571
Type examination certificate:01/205U/5348.00/22
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, November 2, 2022
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

I dettagli e i dati qui riportati sono stati attentamente verificati. Le immagini possono differire dagli originali. Altri dati tecnici possono essere trovati nei manuali. Salvo modifiche tecniche o errori.

Generato il 14/05/2025, 15:43