EX-RSS16-I2-D-10M-3G/D-DU
EX-RSS16-I2-D-10M-3G/D-DU
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
Ordering data
Note (Delivery capacity) |
Not available! |
Product type description |
EX-RSS16-I2-D-10M-3G/D-DU |
Article number (order number) |
103048529 |
EAN (European Article Number) |
4030661620718 |
eCl@ss number, version 12.0 |
27-27-46-01 |
eCl@ss number, version 11.0 |
27-27-24-03 |
eCl@ss number, version 9.0 |
27-27-24-03 |
ETIM number, version 7.0 |
EC001829 |
ETIM number, version 6.0 |
EC001829 |
Approvals - Standards
|
TÜV UKCA |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-7 EN 60079-31 |
Explosion protection category |
3G 3D |
Explosion protection designation |
D II 3D Ex tc IIIC T90°C Dc X |
Manufacturer declaration, zone |
2 22 |
General data
Standards |
EN IEC 60947-5-3 |
Coding |
Individual coding, multiple teaching |
Coding level according to EN ISO 14119 |
High |
Working principle |
RFID |
Housing construction form |
Block |
Installation conditions (mechanical) |
not flush |
Sensor topology |
Sensor for series wiring |
Housing material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Active area |
Glass-fibre, reinforced thermoplastic |
Reaction time, maximum |
100 ms |
Duration of risk, maximum |
200 ms |
General data - Features
Diagnostic output |
Yes |
Short circuit detection |
Yes |
Cross-circuit detection |
Yes |
Series-wiring |
Yes |
Safety functions |
Yes |
Cascadable |
Yes |
Integral system diagnostics, status |
Yes |
Number of LEDs |
2 |
Number of semi-conductor outputs with signaling function |
1 |
Number of fail-safe digital outputs |
2 |
Safety classification |
Standards |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
6.30 x 10⁻¹¹ /h |
PFD value |
1.50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data
Actuating panels |
front side rear from head |
Active area |
lateral front side cover-side |
Mounting |
2 x M5, Cylinder head screw |
Tightening torque of the fixing screws |
2 Nm |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switch distance, typical |
15 mm |
Assured switching distance "ON" Sao |
12 mm |
Assured switching distance "OFF" Sar |
30 mm |
Hysteresis (Switching distance), maximum |
2 mm |
Repeat accuracy R |
0.5 mm |
Mechanical data - Connection technique
Note (length of the sensor chain) |
Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) |
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Length of cable |
10 m |
Mechanical data - Dimensions
Length of sensor |
91 mm |
Width of sensor |
52 mm |
Height of sensor |
30 mm |
Ambient conditions
Degree of protection |
IP65 IP67 |
Ambient temperature |
-25 ... +60 °C |
Storage and transport temperature |
-25 ... +85 °C |
Relative humidity, maximum |
93 % |
Note (Relative humidity) |
non-condensing non-icing |
Restistance to shock |
30 g / 11 ms |
Permissible installation altitude above sea level, maximum |
2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0.8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
Operating current, minimum |
0.5 mA |
No-load supply current I0, typical |
100 mA |
Rated operating voltage |
24 VDC |
Operating current |
2,100 mA |
Required rated short-circuit current |
100 A |
Time to readiness, maximum |
2,000 ms |
Switching frequency, maximum |
1 Hz |
Utilisation category DC-12 |
24 VDC / 0.05 A |
Electrical data - Safety digital inputs
Current consumption of the safety inputs |
5 mA |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) |
1,000 mA |
Output current, (fail-safe output), maximum |
1 A |
Design of control elements |
p-type |
Voltage drop Ud, maximum |
1 V |
Leakage current Ir, maximum |
0.5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
1 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0.05 A |
Electrical data - Diagnostic outputs
Operating current |
50 mA |
Design of control elements |
p-type |
Voltage drop Ud, maximum |
2 V |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0.05 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0.05 A |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation |
IEC 61000-6-4 |
Status indication
Note (LED switching conditions display) |
Multi-coloured LED: Green, Red LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Accessory
Recommendation (actuator) |
RST16-1 |
Recommended safety switchgear |
PROTECT PSC1 SRB-E-301ST SRB-E-201LC SRB200EXi SRB101EXi |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UKCA certificate
TÜV certification
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Video ID: EX-RSS16-Mr-Safety
103034308 EX-RSS16-I2-D-10M-3G/D
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
UK Declaration of Conformity |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | EX-RSS16-...-3GD |
Type: | See ordering code |
Marking: | D II 3G Ex ec IIC T6 Gc D II 3D Ex tc IIIC T 90 °C Dc |
Description of the component: | Non-contact safety sensor |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Electromagnetic Compatibility Regulations | 2016 | |
Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-3:2013, EN 300 330 V2.1.1:2017, EN ISO 14119:2013, EN ISO 13849-1:2015, IEC 61508 parts 1-7:2010, EN IEC 60079-0:2018, EN IEC 60079-7:2015 + A1:2018, EN 60079-31:2014 |
Approved body for Type Examination: | TÜV Rheinland UK Ltd. 1011 Stratford Road Solihull, B90 4BN ID: 2571 |
Type examination certificate: | 01/205U/5412.00/22 |
Conformity with SI 2016/1107 (Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations) is declared by the manufacturer without involving a conformity assessment center. |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, November 17, 2022 |
Authorised signature Philip Schmersal Managing Director |
EU Declaration of Conformity |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | EX-RSS16-…-3GD |
Type: | See ordering code |
Marking: | D II 3G Ex ec IIC T6 Gc D II 3D Ex tc IIIC T 90 °C Dc |
Description of the component: | Non-contact safety sensor |
Applicable directives: | Machinery Directive | 2006/42/EC |
RED-Directive | 2014/53/EU | |
Explosion Protection Directive (ATEX) | 2014/34/EU | |
RoHS Directive | 2011/65/EU |
Applied standards: | EN 60947-5-3:2013 EN 300 330 V2.1.1:2017 ISO 14119:2013 EN ISO 13849-1:2008 + AC:2009 IEC 61508 parts 1-7:2010 EN 62061:2005 + AC:2010 + A1:2013 EN 60079-0:2012 + A11:2013 EN 60079-7:2015 EN 60079-31:2014 |
Notified body for Type Examination in accordance with the Machinery Directive 2006/42/EC: | TÜV Rheinland Industrie Service GmbH Alboinstr. 56, 12103 Berlin ID n°: 0035 |
EC test certificate in accordance with the Machinery Directive 2006/42/EC: | 01/205/5412.01/15 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
The conformity assessment procedure for explosion protection was carried out in accordance with Article 13 of Directive 2014/34/EU, under the responsibility of the manufacturer K.A. Schmersal GmbH & Co. KG. |
Place and date of issue: | Wuppertal, January 11, 2019 |
Authorised signature Philip Schmersal Managing Director |
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 2024-12-22, 9:53 p.m.