PSC1-C-100-FB2
PSC1-C-100-FB2
- Memory card
- Expandable with safe remote IO modules
- Safe cross communication between up to 4 master controllers
- conversion of the field bus protocols by software
- integrated SD-Bus-Gateway
- Modularly expandable to up to 272 safe inputs / outputs
- Safe spindle monitoring To EN 61800-5-2 (Safe Drive Monitoring) for up to 12 spindles
- 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switching semiconductor outputs
- 14 safe inputs on the base module
- 20 switchable, safe inputs / outputs
- 6 Signalling outputs
- 2 safety relay contacts
Ordering data
| Note (Delivery capacity) |
Not available! |
| Product type description |
PSC1-C-100-FB2 |
| Article number (order number) |
103008453 |
| EAN (European Article Number) |
4030661455143 |
| eCl@ss number, version 12.0 |
27-24-22-07 |
| eCl@ss number, version 11.0 |
27-24-22-07 |
| eCl@ss number, version 9.0 |
27-24-22-07 |
| ETIM number, version 7.0 |
EC000236 |
| ETIM number, version 6.0 |
EC000236 |
General data
| Gross weight |
400 g |
General data - Features
| SD Card Slot |
Yes |
| Master-Slave-Communication (decentralized) |
Yes |
| Master-Master-Kommunikation |
Yes |
| Integrated SD gateway |
Yes |
| Number of pulse outputs (test pulse output) |
6 |
| Number of relay outputs (1-channel) |
2 |
| Number of digital fail-safe inputs |
14 |
| Number of digital fail-safe in-/outputs |
20 |
| Number of fail-safe digital outputs |
4 |
| Number of signalling outputs |
6 |
| Anzahl der Erweiterungsbaugruppen, maximal |
8 |
| Safety classification |
| Performance Level, up to |
e |
| Category |
4 |
| PFH value |
1.22 x 10⁻⁸ /h |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
Mechanical data
| Mounting |
can be clipped into standard rail |
Mechanical data - Connection technique
| Cable section, minimum |
0.2 mm² |
| Cable section, maximum |
2.5 mm² |
| Wire cross-section, minimum |
24 AWG |
| Wire cross-section, maximum |
12 AWG |
| Terminal (mechanical) |
Removable screw terminals |
Mechanical data - Dimensions
| Width |
112.5 mm |
| Height |
100 mm |
| Depth |
115 mm |
Ambient conditions
| Degree of protection |
IP20 |
| Ambient temperature |
+0 ... +50 °C |
| Storage and transport temperature |
-25 ... +70 °C |
| Relative humidity, minimum |
5 % |
| Relative humidity, maximum |
85 % |
| Note (Relative humidity) |
non-condensing |
| Permissible installation altitude above sea level, maximum |
2,000 m |
Ambient conditions - Insulation values
| Overvoltage category |
III |
| Degree of pollution |
2 |
Electrical data
| Operating voltage |
24 VDC -15 % / +20 % |
| Rated operating voltage |
24 VDC |
Electrical data - Universal communication interface
| Designation, Communication interface |
DSUB |
Electrical data - Communication protocols
| Feldbus Protokoll |
CANopen PROFIBUS |
Electrical data - Safety digital outputs
| Rated operating current (safety outputs) |
2,000 mA |
| Design of control elements |
short-circuit proof, p-type (Q2 und Q3) |
Electrical data - Safe relay outputs
| Voltage, Utilisation category AC-15 |
230 VAC |
| Current, Utilisation category AC-15 |
2 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
| Electromagnetic compatibility |
DIN EN 62061 DIN EN 61800-3 |
| Interfering radiation |
DIN EN 61000-6-4 |
| EMC rating |
DIN EN 61000-6-7 DIN EN 61326-3 DIN EN 61000-6-2 |
Scope of delivery
| Scope of delivery |
Backplane bus connector Connector terminals |
Language filter
Datasheet
Software manual
Installation manual
Field bus communication manual
Device description files
Software (Download)
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Video ID: SD-Interface-Mr-Safety
103057167 PSC1-C-100-FB2
- Memory card
- Expandable with safe remote IO modules
- Safe cross communication between up to 4 master controllers
- conversion of the field bus protocols by software
- integrated SD-Bus-Gateway
- Modularly expandable to up to 272 safe inputs / outputs
- Safe spindle monitoring To EN 61800-5-2 (Safe Drive Monitoring) for up to 12 spindles
- 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switching semiconductor outputs
- 14 safe inputs on the base module
- 20 switchable, safe inputs / outputs
- 6 Signalling outputs
- 2 safety relay contacts
103056288 PSC1-E-131-12DI-10DIO
- Expansion module for the product series PSC1-C-100
- 12 digital safe inputs
- 10 switchable safe inputs/outputs
- 2 additional signalling outputs
| EU Declaration of Conformity | ![]() |
| Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
| Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
| Name of the component: | PSC1 |
| Type: | See ordering code |
| Description of the component: | Safety compact controller, with or without drive monitoring; IO expansion module, with or without relay expansion |
| Relevant Directives: | Machinery Directive | 2006/42/EC |
| EMC-Directive | 2014/30/EU | |
| RoHS-Directive | 2011/65/EU |
| Applied standards: | EN 61800-5-2:2017 EN ISO 13849-1:2015 EN 61508 parts 1-7:2010 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
| Notified body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
| EC-Type Examination Certificate: | 01/205/5526.01/21 |
| Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
| Ort und Datum der Ausstellung: | Wuppertal, August 25, 2023 |
![]() |
| Authorised signature Philip Schmersal Managing Director |
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 2025-08-19, 10:51 p.m.