TFH 232 ST-AS UEDR
TFH 232 ST-AS UEDR
- 2 Contacts
- AS-Interface M12 connector
- Protective shield with wide opening
- Low operating height of pedal
- Integrated AS-Interface
- Suitable for AS-i Power24
Ordering data
Note (Delivery capacity) |
Not available! |
Product type description |
TFH 232 ST-AS UEDR |
Article number (order number) |
101215189 |
EAN (European Article Number) |
4030661404486 |
eCl@ss number, version 12.0 |
27-37-12-18 |
eCl@ss number, version 11.0 |
27-37-12-18 |
eCl@ss number, version 9.0 |
27-37-12-18 |
ETIM number, version 7.0 |
EC001258 |
ETIM number, version 6.0 |
EC001258 |
Approvals - Standards
|
cULus ASi-SaW |
General data
Standards |
EN 50295 EN ISO 13849-1 EN ISO 13850 EN IEC 60947-5-1 EN IEC 61508 |
Housing material |
Aluminium |
Housing coating material |
powder-coated |
Material of the housing cover |
Aluminium |
Material of the pedal |
Glass-fibre, reinforced thermoplastic |
Material of the protective shield |
Aluminium |
Colour of the product |
White aluminum |
Gross weight |
1,915 g |
General data - Features
Latching |
Yes |
Suitable for EMERGENCY-OFF |
Yes |
Pressure point |
Yes |
Overlapping contacts |
Yes |
Probing possible |
Yes |
Latching |
Yes |
Number of normally closed (NC) |
1 |
Number of normally open (NO) |
1 |
Safety classification |
Standards |
EN IEC 61508 |
Performance Level, up to |
c |
Category |
1 |
PFH value |
1.14 x 10⁻⁶ /h |
Note (PFH-value) |
up to max. 36,500 switching cycles/year |
Safety Integrity Level (SIL), suitable for applications in |
1 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
200,000 Operations |
Mechanical data - Connection technique
Termination |
Connector plug M12, 5-pole |
Mechanical data - Dimensions
Width |
170 mm |
Height |
189 mm |
Depth |
274 mm |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
-25 ... +60 °C |
Storage and transport temperature |
-25 ... +85 °C |
Relative humidity, minimum |
30 % |
Relative humidity, maximum |
95 % |
Note (Relative humidity) |
non-condensing non-icing |
Resistance to vibrations |
10 … 150 Hz, amplitude 0.35 mm / 5 g |
Restistance to shock |
15 g / 11 ms |
Ambient conditions - Insulation values
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Current consumption |
50 mA |
Switching element |
NO contact, NC contact |
Maximum switching frequency |
3,600 /h |
Electrical data - AS Interface
Rated operating voltage |
18 ... 31.6 VDC (Protection against polarity reversal) |
Electrical data - AS-Interface specification
AS-i Version |
V 3.0 |
AS-i Profile |
S-0.B.F.F |
AS-i, IO-Code |
0x0 |
AS-i, ID-Code |
0xB |
AS-i, ID-Code1 |
0xF |
AS-i, ID-Code2 |
0xF |
AS-i Input, Channel 1 |
Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 |
Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 |
Solenoid control |
AS-i Outputs, DO 0 … DO 3 |
No Function |
AS-i Parameter bits, P0 |
Channel 2 switched |
AS-i Parameter bits, P1 ... P3 |
No function |
Note (AS-i Parameter bits) |
Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address |
0 |
Note (AS-i Input module address) |
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
AS interface safety at work certificate
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Diagram
Product in the environment (application)
Operating principle
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 2024-11-15, 4:22 a.m.