PROTECT-SELECT-CC

Item number: 101215377

  • Simple and flexible parameter setting
  • No programming skills required
  • 18 safe inputs for the redundant inquiry of all common safety sensors
  • 4 safety semi-conductor outputs
  • 2 safety relay outputs
  • 4 optional signalling outputs
  • Replaces up to 8 safety-monitoring modules up to PL e / SIL 3
  • Error and status messages in plain text
  • Multilingual menu navigation via colour display

Ordering data

Product type description

PROTECT-SELECT-CC

Article number (order number)

101215377

EAN (European Article Number)

4030661445403

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

TÜV

cULus

CCC

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-1

EN 60068-2-2

EN 61496

Housing material

Polyamide / V0

Gross weight

480 g

General data - Features

Short circuit detection

Yes

Wire breakage detection

Yes

Cross-circuit detection

Yes

Removable Terminals

Yes

Start input

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Reset edge detection

Yes

Start-up test

Yes

Earth connection detection

Yes

Integral system diagnostics, status

Yes

Integrated Display, Supply Voltage

Yes

Number of pulse outputs (test pulse output)

3

Number of relay outputs (1-channel)

2

Number of fail-safe analogue inputs

2

Number of digital fail-safe inputs

14

Number of digital fail-safe in-/outputs

4

Number of fail-safe digital outputs

4

Number of signalling outputs

4

Safety classification

Standards

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 62061

EN IEC 61508

Performance Level, up to

e

Category

4

Diagnostic Coverage (DC) Level

99

PFH value

1.78 x 10⁻⁸ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Hardware fault tolerance (HFT)

1

Demand rate

high or continuous

Safe Failure Fraction (SFF), minimum

90

Safety classification - Relay outputs

Performance Level, up to

e

Category

4

Notice

Valid for dual channel and 60% relay load

Safety Integrity Level (SIL), suitable for applications in

3

Safety classification - Safety inputs 2-channels

Performance Level, up to

e

Category

4

Safety Integrity Level (SIL), suitable for applications in

3

Safety classification - Safety inputs 1-channel

Performance Level, up to

d

Category

2

Safety Integrity Level (SIL), suitable for applications in

2

Safety classification - Safety outputs 1-channel

Performance Level, up to

d

Category

2

Safety Integrity Level (SIL), suitable for applications in

2

Safety classification - Safety outputs 2-channels

Performance Level, up to

e

Category

4

Safety Integrity Level (SIL), suitable for applications in

3

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal designations

IEC 61131-2

IEC/EN 60947-1

Termination

rigid or flexible

Cable section, minimum

0.25 mm²

Cable section, maximum

2.5 mm²

Terminal (mechanical)

Removable cage terminals

Mechanical data - Dimensions

Width

52.5 mm

Height

100 mm

Depth

118 mm

Ambient conditions

Degree of protection

IP20

Degree of protection of the mounting space

IP54

Ambient temperature

-25 ... +55 °C

Storage and transport temperature

-25 ... +75 °C

Relative humidity, minimum

15 %

Relative humidity, maximum

90 %

Note (Relative humidity)

non-condensing

Resistance to vibrations

10 … 57 Hz, amplitude 0.75 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Overvoltage category

III

Degree of pollution

2

Electrical data

Operating voltage

12 VDC -10 % / +10 %

Current consumption at 24V, maximum

500 mA

No-load supply current I0, typical

500 mA

Rated operating voltage

12 VDC

Required rated short-circuit current

1,000 A

Note (Electrical data, Fuse rating)

slow blow

Switching frequency, maximum

0.1 Hz

Material of the contacts, electrical

Tin

Electrical fuse rating, maximum

3 A

Electrical data - Safety digital inputs

Switching thresholds

-3 V … 2 V (LOW)

18 V … 28.8 V

Current consumption at 24 V

6 mA

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

700 mA

Design of control elements

short-circuit proof, p-type / n-type (Q0/0N and Q1/1N)

short-circuit proof, p-type (Q2 und Q3)

Leakage current Ir, maximum

2 mA

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-1

250 VAC

Current, Utilisation category AC-1

4 A

Voltage, Utilisation category DC-1

24 VDC

Current, Utilisation category DC-1

4 A

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

3 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

4 A

Electrical data - Diagnostic outputs

Operating current

100 mA

Design of control elements

Limited short-circuit protection, p-type

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Other data

Note (applications)

Safety sensor

Guard system

Emergency-Stop button

Pull-wire emergency stop switches

Safety light curtain

Language filter

UKCA Declaration of Conformity

SISTEMA-VDMA library

Download the latest version of Adobe Reader

Video ID: Mr-Safety-Protect-Select

(Vimeo)


EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:PROTECT SELECT-CC 1)
1) SYS Firmware: 1.1.7 or higher
Hardware: FOMP or higher
Type:See ordering code (standard version)
Description of the component:Multifunctional safety controller
Relevant Directives:Machinery Directive2006/42/EC
 EMC-Directive2014/30/EU
 RoHS-Directive2011/65/EU
Applied standards:EN ISO 13850:2015
EN ISO 13849-1:2015
IEC 61508 parts 1-7:2010
EN 62061:2005 + Cor.:2010 + A1:2013 + A2:2015
Notified body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
EC-Type Examination Certificate:01/205/5352.01/19
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, May 25, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director
UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:PROTECT-SELECT-CC 1)
1) SYS Firmware: 1.1.7 or higher
Hardware: FOMP or higher
Type:See ordering code (standard version)
Description of the component:Multifunctional safety controller
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Electromagnetic Compatibility Regulations2016
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:EN ISO 13850:2015
EN ISO 13849-1:2015
IEC 61508 parts 1-7:2010
EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Approved body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
Type examination certificate:01/205/5352.01/19
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, May 25, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 2024-06-25, 12:50 p.m.