schmersal_s_icon.png

SFB-PN-IRT-8M12-IOP

Codice prodotto: 103015478

  • Safety fieldbox for PROFINET/PROFIsafe
  • For connection of up to 8 safety switching devices
  • Integrated dual-port switch, IRT-capable
  • Protection class IP67

Ordering data

Note (Delivery capacity)

Non più disponibile!

Product type description

SFB-PN-IRT-8M12-IOP

Article number (order number)

103015478

EAN (European Article Number)

4030661516875

eCl@ss number, version 12.0

27-24-26-04

eCl@ss number, version 11.0

27-24-26-04

eCl@ss number, version 9.0

27-24-26-04

ETIM number, version 7.0

EC001599

ETIM number, version 6.0

EC001599

Approvals - Standards

Certificates

TÜV

cULus

UKCA

General data

Standards

EN IEC 61131-1

EN IEC 61131-2

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Housing material

Materiale sintetico, Poliamide PA 6 GF

Material of the identification label

materiale sintetico, poliammide PA

Material of viewing window

Poliammide PACM12

Material of electronic encapsulation

Poliuretano 2K PU

Gross weight

655 g

General data - Features

Integral system diagnostics, general

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 62061

EN IEC 61508

Safety classification - Safety inputs 2-channels

Performance Level, up to

e

Category

4

Diagnostic Coverage (DC) Level

99 %

PFH value

3,00 x 10⁻⁹ /h

PFDavg

2,60 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Response time of local safety input ⇒ Fieldbus, maximum

20 ms

Notice

Il modulo SFB è conforme ai requisiti come PDDB (interruttori di prossimità con comportamento definito in condizioni di guasto) secondo EN 60947-5-3 in collegamento con sensori magnetici (2 contatti NC) fino a PLe / SIL 3.

Safety classification - Safety inputs 1-channel

Performance Level, up to

d

Category

2

Diagnostic Coverage (DC) Level

90 %

PFH value

2,30 x 10⁻⁷ /h

PFDavg

2,00 x 10⁻²

Safety Integrity Level (SIL), suitable for applications in

1

Mission time

20 Year(s)

Response time of local safety input > Fieldbus, maximum

20 ms

Test interval for error detection

10 s

Safety classification - Safety outputs 1-channel

Performance Level, up to

d

Category

2

Diagnostic Coverage (DC) Level

90 %

PFH value

1,00 x 10⁻⁷ /h

PFDavg

8,80 x 10⁻³

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Reaction time Fieldbus > local safety output

50 ms

Test interval for error detection

F_WD_Time impostato

Safety classification - Safety outputs 2-channels

Performance Level, up to

d

Category

2

Diagnostic Coverage (DC) Level

90 %

PFH value

1,00 x 10⁻⁷ /h

PFDavg

8,80 x 10⁻³

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Reaction time Fieldbus > local safety output

50 ms

Mechanical data

Mounting

Viti

Type of the fixing screws

2x M6

Tightening torque of the fixing screws, maximum

3 Nm

Mechanical data - Connection technique

Termination

M12 Connettore femmina incorporato / -connettore maschio

Terminal connector, Input/Output

X0 - X7: M12, 8 poli, codifica A

Terminal Connector, Power I/O

M12-POWER, 4 poli, codifica T

Terminal Connector, Field bus

M12, 4 poli, con codifica D

Tightening torque of electrical connection

1 Nm

Tightening torque of electrical connection, maximum

1,5 Nm

Mechanical data - Dimensions

Length

222,8 mm

Width

63 mm

Height

36,1 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-25 ... +55 °C

Storage and transport temperature

-25 ... +70 °C

Relative humidity, minimum

10 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non condensante

Resistance to vibrations

10 … 150 Hz, ampiezza 0,35 mm / 5 g

Restistance to shock

30 g / 11 ms

Protection class

III

Permissible installation altitude above sea level, maximum

2.000 m

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

Current consumption

200 mA

Rated operating voltage

24 VDC

Operating current

10.000 mA

Note (Electrical data, Fuse rating)

Necessità di fusibile esterno

Time to readiness, maximum

8.000 ms

Device Watchdog Time

10 ms

Device Acknowledgement Time, maximum

25 ms

Reaction Time Safety Input, maximum

20 ms

Reaction Time Safety Output, maximum

50 ms

Electrical data - Communication protocols

Feldbus Protokoll

PROFINET / PROFIsafe

Fieldbus specification

V2.3, Conformance Class C

Specification safety fieldbus

V2.4

Fieldbus properties

Media Redundancy Protocol (MRP)

Fast Start Up

Fieldbus network load class

3

Transfer rate

100 Mbit/s Full Duplex

Adressing

Discovery and Configuration Protocol (DCP)

Integrated switch

Dual Port, 100 Mbit/s, IRT fähig

Fieldbus services

I&M0 ... I&M3, SNMP, LLDP

Service interface

WEB-Interface HTTP

Electrical data - Safety digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Classification ZVEI CB24I, Source

C1

Classification ZVEI CB24I, Sink

C1

Electrical data - Test pulse output

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

LED status display - LED 01

LED status

LED Error collegamento dispositivo

LED position

E: 0 ... 7

LED colour

verde/rosso

LED status display - LED 02

LED status

LED Input collegamento dispositivo

LED position

I: 0 ... 7

LED colour

giallo

LED status display - LED 03

LED status

LED Link porta Ethernet

LED position

L: P1 + P2

LED colour

verde

LED status display - LED 04

LED status

LED Activity porta Ethernet

LED position

A: P1 + P2

LED colour

verde

LED status display - LED 05

LED status

LED System Failure

LED position

"SF": Modulo

LED colour

verde/rosso

LED status display - LED 06

LED status

LED Bus Failure

LED position

"BF": Modulo

LED colour

rosso

LED status display - LED 07

LED status

LED Error Fieldbox

LED position

"Err": Modulo

LED colour

verde/rosso

LED status display - LED 08

LED status

LED Power (alimentazione) scatola di connessione

LED position

"Pwr": Modulo

LED colour

verde

Other data

Note (applications)

Safety Field Box con I/O decentralizzati

Filtro lingua

Certificazione UL

File di descrizione dispositivo

Download dell'ultima versione di Adobe Reader

Video ID: Mr-Safety-SFB-PN

(Vimeo)


103040357 SFB-PN-IRT-8M12-IOP-V2
  • Safety fieldbox for PROFINET/PROFIsafe
  • For connection of up to 8 safety switching devices
  • Integrated dual-port switch, IRT-capable
  • Protection class IP67

Dichiarazione di conformità UE LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Dichiarazione:Si dichiara con la presente che i seguenti componenti, sulla base della loro progettazione e costruzione, sono conformi ai requisiti delle direttive europee sotto elencate.
Denominaz. del componente:SFB
Tipo:vedere codice prodotto
Descrizione del componente:Safety Field Box (modulo IO con interfaccia bus di campo)
Direttive rilevanti:Direttiva Macchine2006/42/CE
 Direttiva EMC2014/30/UE
 Direttiva RoHS2011/65/UE
Norme armonizzate correlate:EN 61131-2:2007
EN 60947-5-3:2013
EN ISO 13849-1:2015
IEC 61508 parte 1-7:2010
Organismo notificato per la certificazione:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
Organismo notificato N.: 0035
Certificato CE di conformità del tipo:01/205/5878.00/22
Responsabile per la documentazione tecnica:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Luogo e data di emissione:Wuppertal, 4 maggio 2022
 GRA_SIG_ksig-y24
 Firma del legale rappresentante
Philip Schmersal
Amministratore delegato
UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:SFB-PN-IRT
SFB-EIP
Type:See ordering code
Description of the component:Safety fieldbox (IO module with fieldbox interface)
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Electromagnetic Compatibility Regulations2016
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:EN 61131-2:2007
EN 60947-5-3:2013
EN ISO 13849-1:2015
EN 61508 parts 1-7:2010
Approved body for Type Examination:TÜV Rheinland UK Ltd.
1011 Stratford Road
Solihull, B90 4BN
ID: 2571
Type examination certificate:01/205U/5878.01/23
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, October 16, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

I dettagli e i dati qui riportati sono stati attentamente verificati. Le immagini possono differire dagli originali. Altri dati tecnici possono essere trovati nei manuali. Salvo modifiche tecniche o errori.

Generato il 26/08/2025, 15:21