EX-T3Z 068-22YR-1637
EX-T3Z 068-22YR-1637
Product type description: EX-T3Z 068 -(1)YR |
(1) | |
11 | 1 NO contacts/1 NC contact |
22 | 2 NO contacts/2 NC contact |
33 | 3 NO contacts/3 NC contacts |
(2) | |
1637 | Gold-plated contacts |
- 2 switches in one enclosure
- Metal enclosure
- two-side operation / wire up to 2 x 50 m long
- Robust design
- Low actuating force
- Pull-ring reset
- wire pull and breakage detection
- Ex-Zone 21 and 22
Ordering data
Product type description |
EX-T3Z 068-22YR-1637 |
Article number (order number) |
101209850 |
EAN (European Article Number) |
4030661386430 |
eCl@ss number, version 12.0 |
27-37-12-01 |
eCl@ss number, version 11.0 |
27-37-12-01 |
eCl@ss number, version 9.0 |
27-37-12-01 |
ETIM number, version 7.0 |
EC002033 |
ETIM number, version 6.0 |
EC002033 |
Approvals - Standards
Certificates |
TÜV CCC CCC EX |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-31 |
Explosion protection zones |
21 |
Explosion protection category |
2D |
Explosion protection designation |
D II 2D Ex tb IIIC T90°C Db |
General data
Standards |
ABNT NBR IEC 60947-5-1 ABNT NBR IEC 60947-5-5 EN ISO 13850 EN IEC 60947-5-1 EN IEC 60947-5-5 |
Housing material |
Grey cast iron, painted |
Material of the housing cover |
Grey cast iron, painted |
Length of the wire, maximum |
50 m |
Gross weight |
4,650 g |
General data - Features
Reset by pull ring |
Yes |
Number of auxiliary contacts |
2 |
Number of safety contacts |
2 |
Safety classification |
Standards |
EN ISO 13849-1 |
Mission time |
20 Year(s) |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
100,000 Operations |
Mechanical data
Actuating element |
Roller lever N300 |
Mechanical life, minimum |
50,000 Operations |
Positive break angle |
32 ° |
Actuating force, maximum |
50 N |
Note (Actuating force) |
30 N in wire direction |
Actuation direction |
Each time 75° right-hand side and left-hand side rotation |
Positive break force, minimum |
50 N |
Positive break torque |
0.2 Nm |
Mechanical data - Connection technique
Termination |
Screw terminals M20 x 1.5 |
Cable section, minimum |
0.75 mm² |
Cable section, maximum |
1.5 mm² |
Note |
All indications including the conductor ferrules. |
Ambient conditions
Degree of protection |
IP65 IP66 |
Ambient temperature |
-20 ... +60 °C |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
250 VAC |
Rated impulse withstand voltage Uimp |
4 kV |
Electrical data
Thermal test current |
10 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
2.5 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
6 A |
Switching element |
NO contact, NC contact |
Switching principle |
Snap action |
Material of the contacts, electrical |
Silver |
Note
Note (General) |
At 3 m distance intermediate wire supports are required, see accessories |
Language filter
Datasheet
Operating instructions and Declaration of conformity
IECEx certification
INMETRO certification
TÜV certification
BG-test certificate
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Dimensional drawing miscellaneous
Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 4/23/2024, 4:47 AM