schmersal_s_icon.png

BWU3565

Item number: 103016677

Downloads

TraceParts CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
  • Suitable for AZM 400
  • Safe active AS-i distributor
  • Connections for profile cable AS-i & AUX
  • With 2 fail-safe inputs for OSSDs and one digital output that is not fail-safe
  • M12, 8-pole connecting cable 1 m
  • Protection class IP67

Ordering data

Product type description

BWU3565

Article number (order number)

103016677

EAN (European Article Number)

4030661508917

eCl@ss number, version 12.0

27-24-26-04

eCl@ss number, version 11.0

27-24-26-04

eCl@ss number, version 9.0

27-24-26-04

ETIM number, version 7.0

EC001599

ETIM number, version 6.0

EC001599

General data

Standards

EN IEC 62026-2

EN IEC 62061

EN ISO 13849-1

Housing material

Plastic

Reaction time, maximum

11 ms

Gross weight

140 g

General data - Features

Safety functions

Yes

Integral system diagnostics, status

Yes

Safety classification

Standards

EN IEC 62061

Performance Level, up to

e

Category

4

PFH value

5.18 x 10⁻⁹ /h

PFD value

6.19 x 10⁻⁷

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data - Connection technique

Length of cable

1 m

Termination

Cable connector M12, 8-pole, A-coded

Material of the cable

PUR

Mechanical data - Dimensions

Width

60 mm

Height

45 mm

Depth

19 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-20 ... +60 °C

Storage and transport temperature

-30 ... +85 °C

Resistance to vibrations

10 … 55 Hz, amplitude 0.5 mm

Restistance to shock

15 g / 11 ms

Electrical data - AS Interface

Rated operating voltage

21.6 ... 31.6 VDC

AS-i Current consumption, maximum

60 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 2.1

AS-i Profile

S-7.B.F.1

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0

Digital output, Motor control system

AS-i Outputs, DO 1 … DO 3

No Function

AS-i Parameter bits, P0

Control system watchdog

AS-i Parameter bits, P1

Diagnostics signal safety switchgear (inverted)

AS-i Parameter bits, P2 ... P3

No function

Note (AS-i Parameter bits)

Set the parameter outputs to "1111" (0xF)

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Electrical data - Auxiliary voltage

Operating voltage

24 VDC -15 % / +10 % (stabilised PELV power supply)

Rated operating voltage

24 VDC

Status indication

Note (LED switching conditions display)

(1) green/red LED (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected

(2) LED green: AUX-Power available

(3) LED yellow: S1 = Status safety input 1

(4) LED yellow: S2 = Status safety input 2

(5) LED yellow: I1 = Status input I1

(6) LED yellow: o1 = Status output o1

Note

Note voltage AUX DC

stabilised PELV power supply


Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.