schmersal_s_icon.png

HHSNH125-BL-RT-MP

Item number: 103044304

Downloads

ePLAN Data
SISTEMA Data
  • hygienic design
  • with or without mounting plate
  • lockable with a lock

Ordering data

Product type description

HHSNH125-BL-RT-MP

Article number (order number)

103044304

EAN (European Article Number)

4030661618036

eCl@ss number, version 12.0

27-37-14-03

eCl@ss number, version 11.0

27-37-14-03

eCl@ss number, version 9.0

27-37-14-03

ETIM number, version 7.0

EC000216

ETIM number, version 6.0

EC000216

Approvals - Standards

Certificates

hygiene tested

General data

Standards

EN IEC 60947-5-1

EN IEC 60204-1

DIN EN 1672-2

ANSI/UL 60947-1

ANSI/UL 60947-4-1A

Versions

Front plate mounting

Design

Square

Note (Installation condition)

Recess for assembly 90 mm x 90 mm

Toggle

long

Sealing type

Membrane

Lip gaskets

Material of the operators

Plastic

Material of the front ring

stainless steel

Colour of the operating element

Red

Colour of the front ring

Silver

Colour of the bellows

Blue

Gross weight

220 g

General data - Features

Latching

Yes

Number of switch positions

1

Mechanical data

Latching position

right

Mechanical life, minimum

100,000 Operations

Switching angle, right

90 °

Mounting

central nut

Tightening torque of the screw

2 Nm

Tightening torque of nuts, maximum

4 Nm

Mechanical data - Connection technique

Termination

Screw terminals

Cable section, minimum

4 mm², rigid

2.5 mm², flexible

Cable section, maximum

50 mm², rigid

35 mm², flexible

Note

All indications including the conductor ferrules.

Wire cross-section

0 AWG

Tightening torque of Clips

2.5 Nm

Mechanical data - Dimensions

Mounting height

37 mm

Note (Mounting height)

Height in front of the front panel.

Mounting depth

96 mm

Note (Mounting depth)

Depth behind front panel including switching block

diameters for the actuating heads

45 mm

Length of the handle

52.5 mm

Thickness, of the front panel, minimum

1.5 mm

Thickness of the front panel, maximum

6 mm

Note

Size mounting plate 110 mm x 110 mm

Ambient conditions

Degree of protection

IP67

IP69K

Ambient temperature

+0 ... +80 °C

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

8 kV

Electrical data

Thermal test current

125 A

Rated operating voltage

690 VAC

Required rated short-circuit current

25,000 A

Switching principle

Slow action

Other data

Note (applications)

Main switch as emergency stop version with red toggle and yellow plate

Disconnect Switch, Product line H400, Type series H412, 3 pole ON-OFF switch, Front mounting switch

Scope of delivery

Note (scope of delivery, number and type)

Contact carier SMF-SG is included in delivery

with mounting plate and, if applicable, yellow backing plate

EU Conformity Declaration
EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:H program
Type:See ordering code
Description of the component:Command and signalling devices optionally as indicator lights, push buttons, illuminated push buttons, mushroom head impact buttons and switches, selector switches and selector buttons in conjunction with contact element and light elements CLP as well as potentiometer drives, step selector switches and main switches.
Relevant Directives:Low Voltage Directive2014/35/EU
 EMC-Directive2014/30/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 60947-5-1:2017 + AC:2020
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, June 18, 2024
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 12/18/2024, 7:42 AM