HINGED SAFETY SWITCHES TVS410ST1-11/01AN
HINGED SAFETY SWITCHES TVS410ST1-11/01AN
Downloads
Product type description: TVS 410 (1)-(2)(3)(4) |
(1) | |
SK | Screw connection |
CC | Cage clamp |
ST1 | M12 connector bottom |
ST2 | M12 connector top |
(2) | |
11/11 | 2 NC contacts / 2 NO contacts (Caution! According to EN 60204-1, the versions with connector must only be used in PELV circuits. Only for ST1, ST2) |
(3) | |
U | adjustable switching angle |
I | Mounting inside (with fixed switching angle 3°) |
A | Mounting outside (with fixed switching angle 3°) |
(4) | |
without | no assembly end stops |
N | with alignment aid |
- connector plug M12, 8-pole, bottom
- with fixed switching angle
- Metal enclosure
- Good resistance to oil and petroleum spirit
- For left or right hinged doors
- 141 mm x 115 mm x 21,5 mm
- Simple mounting, suitable for all conventional profile systems (30 … 60 mm)
Ordering data
Note (Delivery capacity) |
Not available! |
Product type description |
HINGED SAFETY SWITCHES TVS410ST1-11/01AN |
Article number (order number) |
101184463 |
eCl@ss number, version 12.0 |
27-27-06-09 |
eCl@ss number, version 11.0 |
27-27-06-09 |
eCl@ss number, version 9.0 |
27-27-06-09 |
ETIM number, version 7.0 |
EC002591 |
ETIM number, version 6.0 |
EC002591 |
General data
Housing material |
Metal, zinc die-cast |
Colour of the housing |
Black |
Gross weight |
640 g |
General data - Features
Mounting outside |
Yes |
Alignment aid |
Yes |
Number of auxiliary contacts |
2 |
Number of safety contacts |
2 |
Safety classification |
Standards |
BG-GS-ET-15 EN ISO 13849-1 EN IEC 60947-5-1 |
Mission time |
20 Year(s) |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
2,000,000 Operations |
Mechanical data
Mechanical life, minimum |
1,000,000 Operations |
Positive break angle |
5 ° |
Opening angle |
180° |
Mechanical data - Connection technique
Termination |
Connector plug M12, 8-pole, bottom Connector M12 |
Mechanical data - Dimensions
Length of sensor |
21.5 mm |
Width of sensor |
141 mm |
Height of sensor |
115 mm |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
-25 ... +65 °C |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
250 VAC |
Rated impulse withstand voltage Uimp |
2.5 kV |
Electrical data
Thermal test current |
2.5 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
4 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1 A |
Switching element |
NO contact, NC contact |
Switching principle |
Slow action |
Maximum switching frequency |
1,200 /h |
Material of the contacts, electrical |
Silver-nickel alloy 10 |
Note
Note (General) |
Closed guard device = 0° in contact switch travel diagrams. The factory-set switching angle is 3°. Until the limit of the mechanical life has been reached the angle can increase up to 8° under normal wear-out conditions. The positive break angle is 10°. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Dimensional drawing basic component
Dimensional drawing basic component
Dimensional drawing actuator
Switch travel diagram
Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 11/24/2024, 1:25 PM