IFL (1)-(2)(3)-(4)(5)(6)(7)(8)-(9)


(1)
2Switching distance 2 mm
4Switching distance 4 mm
BQuasi-embeddable

(2)
12Cylinder, thread M12, metal
120Cylinder, thread M12, plastic

(3)
withoutStandard body
MMiniature body
LLong design

(4)
01Opener (NC)
10Normally open contact (NO)
10/01NO contact / NC contact with wiring compartment
111 NO contact / 1 NC contact antivalent

(5)
withoutCable
STMale connector
TConductor with strain relief

(6)
withoutStandard connector version
2Alternative conector version

(7)
Nn-type
Pp-type

(8)
KMax. fuse rating
1pulsed

(9)
2033Stainless steel enclosure
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • Metal enclosure
  • AC 2-wire
  • higher switching distance
  • Design M12

Ordering data

Product type description

IFL 4B-12-10

Article number (order number)

101141562

EAN (European Article Number)

4030661122601

eCl@ss number, version 12.0

27-27-40-01

eCl@ss number, version 11.0

27-27-01-01

eCl@ss number, version 9.0

27-27-01-01

ETIM number, version 7.0

EC002714

ETIM number, version 6.0

EC002714

Approvals - Standards

Certificates

CCC

General data

Standards

DIN VDE 0660-208

EN IEC 60947-5-2

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

Quasi-embeddable

Note (Installation condition)

Steel: x ≥ 2.4 mm

Other metal: x ≥ 1.2 mm

Housing material

Brass

Housing coating material

nickel-plated

Active area

Plastic

Material of the nuts

Nickel plated brass

Gross weight

100 g

General data - Features

Integral system diagnostics, status

Yes

Number of cable wires

2

Mechanical data

Tightening torque of nuts, maximum

15 Nm

Note (Tightening torque of nuts)

In the shell core area: max. 500 Ncm

Mechanical data - Switching distances according EN IEC 60947-5-3

Nominal switching distance Sn

4 mm

Mechanical data - Connection technique

Length of cable

2 m

Termination

Cable H03VV-F

Wire cross-section

0.5 mm2

Material of the Cable mantle

PVC

Mechanical data - Dimensions

ISO thread of the sensor

M12

width across flats

17 BK

Length of sensor

71 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-25 ... +70 °C

Protection class

0

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Electrical data

Rated supply frequency, minimum

45 Hz

Rated supply frequency, maximum

65 Hz

Type of voltage range

AC

Operating current, minimum

8 mA

Rated operating voltage

15 ... 250 VAC

Operating current

200 mA

Switching element

Normally open contact (NO)

Protection circuit integrated

inductive interference protection

Switching frequency, approx.

10 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

3.5 V

Current at Voltage drop Ud

0.2 A

Design of control elements

Two-wire

Status indication

Note (Integral System Diagnostics, status )

yellow LED

Language filter

Operating instructions (supplementary sheet/quick guide)

Download the latest version of Adobe Reader

Diagram


Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.