Product type description:

PS216-(1)-(2)-(3)


(1)
T11Slow action 1 NO contact / 1 NC contact
T20Slow action 2 NO contact
T02Slow action 2 NC contacts
T03Slow action 3 NC contacts
T12Slow action 1 NO contact / 2 NC contact
T21Slow action 2 NO contact / 1 NC contact

(2)
withoutCable entry M20
STConnector plug M12 - plastic - bottom

(3)
Q200Traction force 45 N for lengths of wire to 50 m
Q210Traction force 70 N for lengths of wire to 100 m
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • thermoplastic enclosure with foldable latching cover
  • small body
  • vertical mounting
  • Twisting of towing eye not possible
  • Progress function (ballpoint pen principle)
  • LED version available

Ordering data

Product type description

PS216-T11-Q210

Article number (order number)

103032512

EAN (European Article Number)

4030661546216

eCl@ss number, version 12.0

27-27-26-01

eCl@ss number, version 11.0

27-27-26-01

eCl@ss number, version 9.0

27-27-26-01

ETIM number, version 7.0

EC000030

ETIM number, version 6.0

EC000030

Approvals - Standards

Certificates

cULus

CCC

General data

Housing construction form

Norm construction design

Length of the wire, maximum

100 m

Gross weight

120 g

General data - Features

Safety functions

Yes

Number of auxiliary contacts

1

Number of safety contacts

1

Mechanical data

Position of the cable gland

bottom

Mechanical life, minimum

100,000 Operations

Positive break force, minimum

70 N

Actuating speed, minimum

60 mm/min

Actuating speed, maximum

1 m/s

Mechanical data - Connection technique

Termination

Screw terminals M20 x 1.5

Cable section, minimum

0.34 mm²

Cable section, maximum

1.5 mm²

Mechanical data - Dimensions

Length of sensor

32.5 mm

Width of sensor

31 mm

Height of sensor

116 mm

Ambient conditions

Degree of protection

IP66

IP67

Ambient temperature

-30 ... +80 °C

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

250 VAC

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Thermal test current

10 A

Required rated short-circuit current

400 A

Utilisation category AC-15

240 VAC

Utilisation category AC-15

3 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

3 A

Switching element

1 NO contact, 1 NC contacts

Switching principle

Slow action

Material of the contacts, electrical

Silver

Dimensional drawing basic component

Diagram

EU Conformity Declaration
EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:PS216-…-Q200
PS216-…-Q210
Type:See ordering code
Description of the component:Pull-wire switches
Relevant Directives:Low Voltage Directive2014/35/EU
 RoHS-Directive2011/65/EU
Applied standards:DIN EN 60947-5-1:2018
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, March 9, 2020
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595