schmersal_s_icon.png

BDF200-ST1-AS-NH-LTWH-LTWH-LTWH

Item number: 103005639

Downloads

TraceParts CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
Product type description:

BDF 200-(1)-AS-(2)-(3)-(4)-(5)-(6)


(1)
ST1Connector plug M12 - plastic - bottom
ST2Connector plug M12, above

(2)
NHEmergency stop pushbutton without protective collar
NHKEmergency stop with protective collar

(3)
WS 2/3Selector switch, 2/3 switch position
WT 2/3Selector switch, 2/3 switch positions
SW 20Key switch/button, 2 switch positions
LT..Illuminated control push button (selection colour)
LM..Indicator light (selection colour)
DT..Push button (Selection Color)

(4)
LT..Illuminated control push button (selection colour)
LM..Indicator light (selection colour)
DT..Push button (Selection Color)

(5)
LT..Illuminated control push button (selection colour)
LM..Indicator light (selection colour)
DT..Push button (Selection Color)

(6)
withoutwithout indicator lamp G24
G24with indicator lamp G24
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • with connector plug M12 bottom
  • Integrated AS-Interface
  • Pos 1: E-STOP
  • Pos 2: WHITE illuminated pushbutton
  • Pos 3: WHITE illuminated pushbutton
  • Pos 4: WHITE illuminated pushbutton
  • slender shock-proof thermoplastic enclosure
  • to be installed at an ergonomic favourable position
  • to be fitted to commercial-off-the-shelf aluminium profiles

Ordering data

Product type description

BDF200-ST1-AS-NH-LTWH-LTWH-LTWH

Article number (order number)

103005639

EAN (European Article Number)

4030661434391

eCl@ss number, version 12.0

27-37-12-16

eCl@ss number, version 11.0

27-37-12-16

eCl@ss number, version 9.0

27-37-12-16

ETIM number, version 7.0

EC000225

ETIM number, version 6.0

EC000225

Note (Ordering data)

Notice: see ordering code

Approvals - Standards

Certificates

cULus

ASi-SaW

General data

Standards

EN IEC 62026-2

EN ISO 13849-1

EN ISO 13850

EN IEC 60947-5-1

EN IEC 61508

Climatic stress

DIN EN 60068

Housing material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Reaction time, maximum

100 ms

Positions used, position 1

Emergency stop pushbutton

Positions used, position 2

Illuminated pushbutton, white

Positions used, position 3

Illuminated pushbutton, white

Positions used, position 4

Illuminated pushbutton, white

Gross weight

280 g

General data - Features

Indicator lamp

No

Safety classification

Standards

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

1.40 x 10⁻⁸ /h

Note (PFH-value)

up to max. 5,000 switching cycles/year

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, Emergency-Stop button

100,000 Operations

Mechanical life, Command devices

1,000,000 Operations

Mounting

interior mounting holes

Type of the fixing screws

2x M5

Mechanical data - Connection technique

Termination

Connector plug M12, 4-pole, (A-coding)

Mechanical data - Dimensions

Width

40 mm

Height

69 mm

Depth

252.5 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

-25 ... +65 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

10 … 150 Hz, amplitude 0.35 mm / 5 g

Restistance to shock

15 g / 11 ms

Protection class

II

Permissible installation altitude above sea level, maximum

2,000 m

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data - AS Interface

Rated operating voltage

18 ... 31.6 VDC (Protection against polarity reversal)

AS-i Current consumption, maximum

150 mA

Electrical data - AS-Interface specification

Note (AS-i Parameter bits)

Set the parameter outputs to "1111" (0xF)

FID: periphery error

AS-i Version (Safety-Slave)

V 3.0

AS-i Profile (Safety-Slave)

S-7.B.F.F

AS-i Input, Channel 1 (Safety-Slave)

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2 (Safety-Slave)

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Output, DO 0 (Safety-Slave)

Indicator lamp G24 red

AS-i Output, DO 1 (Safety-Slave)

Indicator lamp G24 green

AS-i Output, DO 2 (Safety-Slave)

No Function

AS-i Output, DO 3 (Safety-Slave)

No Function

AS-i AS-i Parameter bits (Safety-Slave), P0 ... P3

No function

AS-i Version (A/B Slave)

V 3.0

AS-i Profile (A/B Slave)

S-7.A.7.F

AS-i Input, DI 0 (A/B Slave)

Command device Position 4

AS-i Input, DI 1 (A/B Slave)

Command device Position 3

AS-i Input, DI 2 (A/B Slave)

Command device Position 2

AS-i Input, DI 3 (A/B Slave)

Command device Position 2

AS-i Output, DO 0 (A/B Slave)

Illuminated signal position 4

AS-i Output, DO 2 (A/B Slave)

Illuminated signal position 2

AS-i Output, DO 1 (A/B Slave)

Illuminated signal position 3

AS-i Output, DO 3 (A/B Slave)

No Function

AS-i AS-i Parameter bits (A/B Slave), P0 ... P3

No function

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Note

Both AS-i slaves can be enabled and disabled through the integrated DIP switch. The addressing must take place via the M12 connector.

Pin assignment

PIN 1

AS-Interface +

PIN 2

n.c.

PIN 3

AS-Interface -

PIN 4

n.c.

EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:BDF200AS
Type:See ordering code
Description of the component:Control panel with or without safety function and integrated AS interface
Relevant Directives:Machinery Directive 1)2006/42/EC
 Low Voltage Directive2014/35/EU
 EMC-Directive2014/30/EU
 RoHS-Directive2011/65/EU
 1) For device versions with safety function
Applied standards:EN 60947-5-1:2017 + AC:2020
1) EN 60947-5-5:1997 + A1:2005 + A11:2013 + A2:2017
1) EN ISO 13849-1:2023
1) EN 61508-1:20101)
1) Notified body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
1) EC-Type Examination Certificate:01/205/5613.01/24
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, June 24, 2024
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director
UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:BDF200AS
Type:See ordering code
Description of the component:Control panel with or without emergency-stop function and integrated AS interface
Relevant legislation:Supply of Machinery (Safety) Regulations 1)2008
 Electrical Equipment (Safety) Regulations2016
 Electromagnetic Compatibility Regulations2016
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
 
 1) For device versions with emergency-stop function
Designated standards:EN 60947-5-1:2017 + AC:2020
EN 60947-5-5:1997 + A1:2005 + A11:2013 + A2:2017 1)
EN ISO 13850:2015
EN ISO 13849-1:2015
IEC 61508 parts 1-7:2010
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, November 18, 2022
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 11/8/2024, 4:57 PM