EX-SLG440-ER-0900-04-H

Item number: 103047627

Downloads

ePLAN Data
SISTEMA Data
  • Ex-Zone 1 and 21
  • Range up to 20m
  • Protected mode
  • Integrated contactor control
  • Beam coding

Ordering data

Product type description

EX-SLG440-ER-0900-04-H

Article number (order number)

103047627

EAN (European Article Number)

4030661619071

eCl@ss number, version 12.0

27-27-27-03

eCl@ss number, version 11.0

27-27-27-03

eCl@ss number, version 9.0

27-27-27-03

ETIM number, version 7.0

EC001832

ETIM number, version 6.0

EC001832

Approvals - Standards

Certificates

ATEX

Explosion protection

Explosion protection: regulations

EN IEC 60079-0

EN 60079-1

EN 60079-28

EN 60079-31

Explosion protection zones

1

21

Explosion protection category

2G

2D

Explosion protection designation

D II 2G Ex db op is IIA T6 Gb

D II 2D Ex op is tb IIIC T80°C Db

General data

Standards

EN IEC 61496-2

EN IEC 62061

EN ISO 13849-1

EN IEC 61496-1

Housing material

Shatterproof glass

Reaction time, maximum

10 ms

General data - Features

Restart interlock (manual reset)

Yes

Contactor control integrated

Yes

Beam coding available

Yes

Blanking function

Yes

7-segment display

Yes

Integral system diagnostics, status

Yes

Integral system diagnostics

Yes

Number of fail-safe digital outputs

2

Number of beams

4

Safety classification

Standards

EN ISO 13849-1

EN IEC 62061

Performance Level, up to

e

Category

4

PFH value

5.14 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

300 mm

Height of the protection field

900 mm

Range, protection field, minimum

4 m

Range, protection field, maximum

20 m

Wave length of the laserdiode

880 nm

Mechanical data - Connection technique

Termination

Connector

Terminal connector, Recipient

Connector plug M12, 8-pole

Terminal, Connector, Transmitter

Connector plug M12, 4-pole

Mechanical data - Dimensions

Width of sensor

100 mm

Ambient conditions

Degree of protection

IP66

Ambient temperature

-25 ... +50 °C

Storage and transport temperature

-25 ... +70 °C

Electrical data

Switching voltage OSSD, HIGH signal

24 V

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum

0.25 A

Design of control elements

short-circuit proof, p-type

Scope of delivery

Scope of delivery

Kit with 2 mounting angles

Accessory

Recommended safety switchgear

SRB-E 301

Note

Note (General)

Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.

EU Conformity Declaration
EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:Series EX-SLC440
Series EX-SLG440
Type:See ordering code
Marking:D II 2G Ex db op is IIA T6 Gb
D II 2D Ex op is tb IIIC T80°C Db
Description of the component:Safety light curtain / safety light grid
Relevant Directives:Machinery Directive 1)2006/42/EC
 EMC-Directive2014/30/EU
 Explosion Protection Directive (ATEX) 2)2014/34/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 61496-1:2013
EN 61496-2:2013
ISO 13849-1:2015
EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
EN IEC 60079-0:2018
EN 60079-1:2014
EN 60079-28:2015
EN 60079-31:2014
Notified body, which approved the full quality assurance system, referred to Appendix IV, 2014/34/EU:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
Notified body for Type Examination:1) TÜV NORD CERT GmbH2) TÜV CYPRUS
 Langemarckstr. 20, 45141 EssenPapaflessa 2, 2235 Latsia, Nicosia
 GermanyCyprus
 ID n°: 0044ID n°: 2261
Type Examination Certificate:1) 44 205 160199102) TÜV CY 22 ATEX 0206673 X
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, January 13, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 10/3/2024, 11:08 AM