SE-400 C EVALUATION UNIT
SE-400 C EVALUATION UNIT
- To monitor 1 safety edge(s)
- 2 safety contacts, STOP 0
- 1 Signalling output
Ordering data
Product type description |
SE-400 C EVALUATION UNIT |
Article number (order number) |
101153920 |
EAN (European Article Number) |
4030661289175 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
TÜV cULus |
General data
Standards |
EN ISO 13849-1 EN ISO 13850 |
Climatic stress |
EN ISO 13856-2 |
Housing material |
Glass-fibre, thermoplastic |
Reaction time, maximum |
32 ms |
Gross weight |
184 g |
General data - Features
Electronic Fuse |
Yes |
Wire breakage detection |
Yes |
Cross-circuit detection |
Yes |
Start input |
Yes |
Feedback circuit |
Yes |
Automatic reset function |
Yes |
Reset edge detection |
Yes |
Reset after disconnection of supply voltage |
Yes |
Earth connection detection |
Yes |
Integral system diagnostics, status |
Yes |
Number of LEDs |
2 |
Number of undelayed semi-conductor outputs with signaling function |
1 |
Number of safety contacts |
2 |
Number of signalling outputs |
1 |
Safety classification |
Performance Level, up to |
e |
Category |
4 |
Control category to EN954 |
4 |
PFH value |
2.47 x 10⁻⁸ /h |
Note (PFH-value) |
up to max. 50,000 switching cycles/year |
Mission time |
20 Year(s) |
Stop-Category |
0 |
Mechanical data
Mechanical life, minimum |
30,000,000 Operations |
Mounting |
Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Length of cable |
200 m |
Termination |
Screw terminals M20 x 1.5 |
Cable section, maximum |
2 x 1.5 mm² |
Note |
All indications including the conductor ferrules. |
Mechanical data - Dimensions
Width |
22.5 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
+5 ... +55 °C |
Resistance to vibrations |
10 … 55 Hz, amplitude 0.15 mm |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Operating voltage |
24 VDC -10 % / +20 % |
Rated operating voltage |
24 VDC |
Operating current |
150 mA |
Rated AC voltage for controls at DC minimum |
21.6 VDC |
Rated control voltage at DC, maximum |
28.8 VDC |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
2 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
3 A |
Electrical power consumption, maximum |
4 W |
Time to readiness, maximum |
32 ms |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-Directive |
Status indication
Indicated operating states |
Safety edge function |
Other data
Note (applications) |
Safety edges |
Note
Note (General) |
The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components. If there it any risk whatsoever, the machine may not be restarted. |
Wiring example
Note (Wiring diagram) |
A Start-Reset-Taster (S) can optionally be connected to the feedback circuit. Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3). The wiring diagram is shown for the de-energised condition. Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-400C up to PL e and Category 4. The feedback circuit monitors the position of the contactors KA and KB. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
TÜV certification
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Wiring example
EU-Konformitätserklärung |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Erklärung: | Hiermit erklären wir, dass die nachfolgend aufgeführten Bauteile aufgrund der Konzipierung und Bauart den Anforderungen der unten angeführten Europäischen Richtlinien entsprechen. |
Bezeichnung des Bauteils: | SE-400 C |
Typ: | siehe Typenschlüssel |
Beschreibung des Bauteils: | Sicherheitsauswertung zur Überwachung optoelektronischer Sicherheits-Schaltleisten der Reihen SE 40/70 mit Sensor-Set SE-SET |
Einschlägige Richtlinien: | Maschinenrichtlinie | 2006/42/EG |
EMV-Richtlinie | 2014/30/EU | |
RoHS-Richtlinie | 2011/65/EU |
Angewandte Normen: | EN ISO 13856-2:2013 EN ISO 13849-1:2015 EN 12978:2003 + A1:2009 |
Benannte Stelle der Baumusterprüfung: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln Kenn-Nr.: 0035 |
EG-Baumusterprüfbescheinigung: | 01/205/5007.02/19 |
Bevollmächtigter für die Zusammenstellung der technischen Unterlagen: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Ort und Datum der Ausstellung: | Wuppertal, 22. März 2019 |
Rechtsverbindliche Unterschrift Philip Schmersal Geschäftsführer |
Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 4/28/2024, 11:35 AM